Table A–2 (Cont.) Error Messages
Message
Recommended Actions
CR, Loopback test failed
CR, Full Duplex test failed
Refer to the
Turbo
board distribution
diskette file A:\Error.txt for more
information and troubleshooting tips
regarding the error message.
These errors are supplemental
network tests that require loopback
connectors for ThinWire or a
TP repeater link for TP testing.
These tests are only available
when diagnostics are run from the
NICSETUP Diagnostic menu.
To test the ThinWire coaxial port
(when present), the board must be
removed from the live network and
the ThinWire connector properly
terminated with a T-connector and
two terminators. Without proper
termination the Loopback or Full
Duplex test will fail.
To test the TP port (when present),
the board must have a valid link to a
TP repeater. The board that supports
TP has a green LED that lights when
the link to the TP repeater is good. If
the green LED does not light, check
TP cabling and TP repeater port.
To test the AUI thick wire port, select
AUI port using board shunt jumper
and connect to AUI repeater. If the
error message persists, board may be
defective. Contact your Digital Sales
Representative.
A–10
Содержание Digital EtherWORKS 3 Turbo
Страница 8: ......
Страница 12: ...Figure 1 Turbo Product Kit PN DE203 AA LJ 02592 TI0 2 4 3 1 5 W 2 W 1 x ...
Страница 13: ...Figure 2 Turbo TP Product Kit PN DE204 AA LJ 02621 TI0 2 4 3 1 W 2 W 1 xi ...
Страница 14: ...Figure 3 Turbo PLUS Product Kit PN DE205 AA LJ 02623 TI0 2 4 3 1 5 W 2 W 1 ThinWire AUI ThickWire J3 6 xii ...
Страница 16: ......
Страница 30: ......
Страница 66: ......