38
DECserver 900GM Installation
Product Specifications
Table 9 lists the DECserver 900GM physical, environmental, and certification
specifications.
Table 9
Operating Specifications
Parameter
DECserver 900GM
DECserver 900GMx
Operating Environment
Operating Temperature
1
5
°
C – 50
°
C (41
°
F – 122
°
F)
5
°
C – 50
°
C (41
°
F – 122
°
F)
Relative Humidity
10% to 95% noncondensing
10% to 95% noncondensing
Altitude
Sea level to 4900 m (16K ft)
Sea level to 4900 m (16K ft)
Power
28.7 W, total power
4.0 A, 5Vdc
0.1 A, 12Vdc
2
0.5 A, 15Vdc
18.2 W, total power
2.5 A, 5Vdc
0.1 A, 12Vdc
2
0.3 A, 15Vdc
Connectors
GM module has four 68-pin bulk connectors.
GMx module has two 68-pin bulk connectors.
DEChub ONE has: one 8-pin MJ, one DB-9, and one 15-pin D-Sub AUI connector.
DEChub ONE-MX has: one 8-pin MJ, one 6-pin MJ (OBR), one DB-9, one 15-pin D-Sub,
and one redundant power connector (D-Sub).
Physical
Height
44.45 cm (17.5 in)
Width
4.45 cm (1.75 in)
Depth
15.25 cm (6 in); 25.40 cm
(10.0 in) with a DEChub ONE
docking station
Weight
1.8 kg (4 lb)
3
Certification
CE, CSA, FCC,TÜV, UL, VCCI.
1
For sites above 4900 m (16,000 ft), decrease the operating temperature specification
by 1.8
°
C for each 1000 m or 3.2
°
F for each 3200 ft.
2
The 12V power in the DEChub 900 is derived from the 15V power source. Although it is
listed separately in the product specification, the 12V requirements are included in the 15V
power total.
3
Include an additional 1.59 kg (3.5 lb) when attached to a DEChub ONE; when attached to
a DEChub ONE-MX, add 2.10 kg (4.63 lb).