Downline Loading the Firmware File
The downline loading is performed through CCI. To access CCI, use the following
procedure:
1.
Connect a terminal to the front panel connector of the DECagent 90.
The communication parameters should be set as follows:
•
9600 baud
•
8 bits
•
No parity
•
1 stop bit
2.
Physically power cycle the DECagent 90. (Remove and replace the agent.)
3.
Before the self-test LED lights, and 10 seconds after power-up, press Ctrl/I on
the terminal keyboard.
4.
At the CCI> prompt, enter the following command:
CCI> load denma.exe
Return
The following appears on the terminal:
Attempting to locate load host
Host AA-00-04-00..... located
Requesting load from host...
Loading from load host...
Image verification in progress.
Image load completed.
Attempting crc check on image loaded.
CCI>
The DECagent 90 is now loaded with its firmware image. The following
message appears if there was an error in the load process. Try loading again.
Invalid load image...
The following message appears if the DECagent 90 could not locate a host:
DENMA -901- Initializing DECagent 90.
DENMA -953- Attempting to locate load host
[ISO8802]
DENMA -953- Attempting to locate load host
[ETHERNET]
DENMA -951- DENMA will retry operation in 4 seconds
DECagent 90 Management 4–25