Digital Equipment DEC WANcontroller 618 Скачать руководство пользователя страница 4

For details of tests and procedures, refer to the panel with the matching  flag (see overleaf).

 

 

 

D

or

ATTENTION

READY

FAULT

Fast Flicker

The problem could be a loose cable
connection. Check all extension
cables are properly connected.
If this does not solve the problem,
continue along this path of the
flowchart.

Test

successful?

(READY state)

B

Perform a module loopback
test on the NIC.

Test

successful?

(READY state)

There is a possible problem
with the NIC.

Do

the system

displays on the processor

card display indicate  that the

software is loaded and

running?

Load the DECNIS software
through the alternative port.
See the DEC Network
Integration Server Software
Installation 
card for the load-
host operating system.

Load

successful?

The problem was a faulty
cable.

D

Replace the distribution
panel.

C

Perform an NCL loopback
test on the faulty port of
the distribution panel.

Test

successful?

All

tests successful?

Check the local modem
and remote connections –
see DEC Network Integration
Server Problem Solving.

D

Replace the section of cable
that failed the test.

Perform NCL loopback test on the extension cables.             
If there is more than one cable, test all cables in sequence:
1.  Test the cable nearest the adapter cable.
2.  If that cable passes the test, test the next section of cable.
3.  Repeat step 2 until all sections of the cable have been         
     tested, or the test fails.

Check the LED display on
the processor card, then see
the Installation and Service
Manual 
for your DECNIS.

LKG-5726–91

C

A

Check the operational
communication ports for the
DEC WANcontroller 618.
Take note of the faulty port(s).

D

Replace the connecting cable.

Load the DECNIS software
through the suspect line.
See the DEC Network
Integration Server Software
Installation 
card for the load-
host operating system.

1

1

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No

D

Replace all the extension
cables.

Problem Solving Flowchart – note the NIC LED   state   and follow the procedure indicated

Do

the system

displays on the processor

card display indicate  that the

software is loaded and

running?

D

If this does not solve your
problem, replace the
distribution panel.

A

Check the operational
communication ports for the
DEC WANcontroller 618.
Take note of the faulty port(s).

C

Perform a module loopback
test on the connecting cable.

Yes

Can you 

load software through

an alternative port on the

DEC WANcontroller

618 or another

NIC?

A

4

Содержание DEC WANcontroller 618

Страница 1: ...Problem Solving DEC WANcontroller 618 Part Number EK A0546 PS 001 Digital Equipment Corporation 1992 All Rights Reserved 1...

Страница 2: ...ber DEC Network Integration Server Problem Solving outlines NCL commands for checking software problems DEC Network Integration Server Event Messages this is an on line text file The file lists event...

Страница 3: ...The NIC is either waiting to load or is load ing software The NIC has passed its module self test and has successfully loaded the software The NIC is disabled The NIC switch is set down The NIC has f...

Страница 4: ...ension cables If there is more than one cable test all cables in sequence 1 Test the cable nearest the adapter cable 2 If that cable passes the test test the next section of cable 3 Repeat step 2 unti...

Страница 5: ...18 3 6 W618 3 7 Port number For example if port 5 is faulty the display reads Slot number 1 Start NCL on the load host 2 Enter the following command 3 Find the attribute operational communication port...

Страница 6: ...kIntegrationServ er Management 1 Disable the NIC move the NIC switch down 2 Attach the 50 way loopback connector male to the port or cable to be tested 3 Run the module loopback test 4 If the test pas...

Страница 7: ...s an error message is displayed Distribution panel port Synchronous cable When the prompt returns enter the following command server name name of physical line circuit name COUNT LENGTH and DATA speci...

Страница 8: ...Connecting cable Extension cable Action Install a new NIC Refer to the Installation and Service Manual for your DECNIS DO NOT do this unless you are a service person Refer to the panel for installing...

Отзывы: