background image

AlphaServer 8400

Alpha Servers    3.221

Step 9—Console Terminal

Console terminal with EIA-232 25-pin DSUB connector and printer required unless otherwise available.

Shielded console cable is included for connection to the console terminal.

VT510-xx

VT510 terminal

LA30N-xx

LA30 printer

LK461-xx/LK46W-xx

Keyboard

Step 10—Expansion—System Cabinet and I/O Expansion Cabinet

Step 10a—System Cabinet

System Cabinet includes one three-phase power regulator with space for two additional three-phase power regulators.
System cabinets shipped after June 1996 (H9F00-FC/FD/FE Rev B03 or greater) include the H7263-AC/AD non-battery
back-up ready power regulator.  See Step 11 for power expansion options for these system cabinets.

Maximum four I/O channels per cabinet allowed. PCI and XMI plug-in units each require one I/O channel connection.

Four lower expansion bays are available for plug-in units. The lower bays accommodate plug-in units as follows.

AlphaServer 8400 System Cabinet

Expansion Bay

Location

Plug-In Unit

(PIU)

Quantity

Expansion Bays Occupied

Lower
Lower
Lower
Lower

Disk plug-in unit

(BA660-AB)

XMI plug-in unit

(DWLMA-AA)

Battery plug-in unit(H7237-AA/AC/CA/CB)
PCI plug-in unit

(DWLPB-AA)

Four maximum
Two maximum
One maximum
Two maximum

Front or Rear
Front and Rear
Front and Rear
Rear only

Step 10b—I/O Expansion Cabinet

I/O Expansion Cabinet includes one three-phase power regulator
-  Provides space for two additional three-phase power regulators

H9F00-BA/BB/BC Rev D03 or later cabinets include the H7263-AC or H7263-AD non-BBU capable power regulator.
Refer to Step 11 for expansion options.

H9F00-BA/BB/BC

I/O expansion cabinet

Three phase power, maximum two per system.

Note: -BA = 60 Hz, 208V, -BB = 50 Hz, 380/416V, -BC = 50/60 Hz, 202V.

Expansion cabinet can be configured to hold all disk plug-in units or combination of disk plug-in units and PCI or XMI
plug-in units.
-  Six expansion bays—two upper and four lower—are available for plug-in units. The two upper bays accommodate

maximum of two disk plug-in units. The four lower bays accommodate plug-in units as follows:

Expansion Bay

Location

Plug-In Unit

(PIU)

Quantity

Expansion Bays Occupied

Upper

Lower
Lower
Lower
Lower

Disk plug-in unit

(BA660-AB)

Disk plug-in unit

(BA660-AB)

PCI plug-in unit

(DWLPB-AB)

XMI plug-in unit

(DWLMA-BA)

Battery plug-in unit (H7237-AA/AC/CA/CB)

Two maximum
Four maximum
Two maximum
Two maximum
One maximum

Front or Rear
Front or Rear
Rear only
Front and Rear
Front and Rear

Step 11

Power Expansion Components

System Cabinet and Expansion Cabinets must be same type; either three-phase or single-phase. Mixing of three-phase
and single-phase cabinets in same system configuration is not allowed.

Determine the need for adding second power regulator by filling in the EPU- Power Configuration Table. Note: The
Power Configuration Table provides a manual method for determining the need of second power regulator. Equivalent
power unit (EPU) is an equivalent value of power used (48 VDC) by each option.

Содержание AlphaServer 8400

Страница 1: ...mbination between these maximums with 1 2 GB sec peak of I O The AlphaServer 8400 5 440 supports up to 14 processors with 4 GB memory two processors with 28 GB of memory and any combination between th...

Страница 2: ...Three CK KFTIA AA cabinet kits 256 MB 512 MB 2 GB or 4 GB of memory BA660 AB StorageWorks Plug in unit PIU 2 GB or 4 3 GB 3 5 SCSI system disk drive 600 MB CD ROM drive DWZZB VW SCSI signal converter...

Страница 3: ...regulators Three Phase power subsystem includes power cord Shielded console cable for connection to console terminal Factory Installed Software 5 300 Operating System Software DIGITAL UNIX base licens...

Страница 4: ...only no other disk or tape connections are supported maximum one per system BN21H 02 SCSI cable Required for XMI systems DWLMA AA XMI plug in unit See Step 6 for details KZMSA AB XMI single ended SCSI...

Страница 5: ...es include processor module with Alpha microprocessor s SMP license and end user product warranty 5 300 Servers 5 350 Servers 5 440 Servers CPU Module Type Operating System 751P2 AX 753P2 AX N A Singl...

Страница 6: ...three KFTHAs DWLPB AA PCI plug in unit with one PCI box for AlphaServer 8400 system cabinet only maximum two per system cabinet two per system Requires one I O channel connection on either KFTIA AA o...

Страница 7: ...from KFTIA FWD port to DWZZB VW in BA661 AA in DWLPB xx PIU BN21K 03 Connects from KFTIA FWD port to DWZZB VW in BA660 AB System cabinet front BN21K 05 10 Connects from KFTIA FWD port to DWZZB VW in B...

Страница 8: ...e ended SCSI cable for connections from PCI RAID controller to BA660 AB system cabinet and BA661 AA KZPSC UB Battery back up for cache memory option for KZPAC or KZPSC controller MS100 BB 8 MB cache m...

Страница 9: ...A and OpenVMS V6 2 1H3 A DIGITAL UNIX patch OSF405 034 is required for dual redundant failover HSJ50 family of CI Storage Array Controllers are supported under OpenVMS V6 2 1H3 with CIPCA AA BA or CIX...

Страница 10: ...rs and SCSI storage options Wide SCSI devices are supported in BA660 AB BA661 AA StorageWorks PIUs or external StorageWorks cabinets BA660 AB BA661 AA support both wide and narrow SCSI 5400 RPM and 72...

Страница 11: ...w SCSI disk drive DS RZ40 VA 9 0 GB 7200 RPM 8 bit Narrow SCSI disk drive Tape Devices TLZ09 VA 8 0 GB DAT 3 5 SCSI tape drive in StorageWorks carrier OpenVMS V6 2 1H3 and DIGITAL UNIX V3 2C required...

Страница 12: ...lers each with 32 MB cache HSZ Traditional License QL 2YJA9 AA RAID HSZ40 Firmware License QL 3J0A9 AA Mirror Firmware HSZ40 Traditional License QL 4DTA9 AA BN21K 20 20 meter cable BN21L 0B 15 meter c...

Страница 13: ...nication Adapter OpenVMS v6 2 1H3 supports two per PCI maximum two per system PBXDA AB PCI Asynchronous 8 port Communication Adapter OpenVMS v6 2 1H3 supports two per PCI maximum two per system DE500...

Страница 14: ...XI01 AA provides up to 48 additional ports DIGITAL UNIX only CXI01 AD Digiboard Asynchronous EPC X Multiport Serial Card with 16 RJ45 Port EPC CON 16 Concentrator uses one EISA slot DIGITAL UNIX one p...

Страница 15: ...are at revision V2 3 or higher CCMAA BA Adapter must be installed in slots 0 7 of a DWLPA AA AB BA BB PCI no restriction for DWLPB AA AB BA BB PCI bus For two system nodes order one CCMAA BA per syste...

Страница 16: ...gulator Provides space for two additional three phase power regulators H9F00 BA BB BC Rev D03 or later cabinets include the H7263 AC or H7263 AD non BBU capable power regulator Refer to Step 11 for ex...

Страница 17: ...ry plug in unit with batteries for battery backup UPS capability maximum one per cabinet Use in system cabinet and or H9F00 BA BB BC expansion cabinet Includes four batteries to support 48 V power reg...

Страница 18: ...ly Media available on layered product CD ROM KZMSA or KZPSA adapter required Included in 5 440 DIGITAL UNIX Base and Expanded Base Servers DIGITAL UNIX Media and Documentation QA MT4AA H8 DIGITAL UNIX...

Страница 19: ...vers QA 5LVAA H8 DIGITAL Enterprise Integration Server for OpenVMS media and documentation DIGITAL NAS Base Server 200 Software DIGITAL NAS 200 Base Server software included with base 5 300 MHz AlphaS...

Страница 20: ...ntal Support for DIGITAL UNIX two CPU systems FM 84DOS 36 36 month Software Supplemental Support for DIGITAL UNIX two CPU systems FM 84DOS 60 60 month Software Supplemental Support for DIGITAL UNIX tw...

Страница 21: ...5 350 CPU modules 754P1 AX 754P2 AX 14 Additional dual 5 440 CPU modules 756P1 AX 756P2 AX 8 KFTIA AA System I O module 4 KFTHA AA System I O module 3 MS7CC BA 128 MB memory 5 MS7CC CA 256 MB memory...

Страница 22: ...equal to value listed under operating system to be used 8 8 FDDI Options Included KFTIA AA I O module optional FDDI daughter card installed DEFPZ AA UA 1 Additional KFTIA AA I O module optional FDDI d...

Страница 23: ...Channel BA655 PIU BA660 PIU Batteries for UPS Expansion Bay for XMI I O Channel PCI I O Channel BA655 PIU BA660 PIU Batteries for UPS System Cabinet I O Expansion Cabinet CD ROM Operator Control Pane...

Страница 24: ...ewed to AS 3260 Australian Standard EN 60950 European Norm Power Requirements 1 Three Phase Power Subsystem 2 US Canada Europe AP Japan Nominal voltage Frequency range Phases Maximum input current pha...

Страница 25: ...4N AEACM BK PUPS plus 15kVA receptacle module 2 L21 30R 3 5 20R2 4N AEACM BN PUPS plus 15kVA receptacle module 2 L6 30R 2 L21 30R 1 5 20R2 4N AEACM PA PUPS plus 15kVA dual receptacle module Module 1...