AlphaServer 8400
Alpha Servers 3.213
Step 6—Storage Controllers (continued)
PCI-based Storage Controllers
KZPAC-AA
PCI one-port SCSI RAID Controller with 4 MB cache memory—Uses one PCI slot. Provides one
fast/wide single-ended connection. Allows RAID levels 0, 1 and 5. Includes RAID Array 230/plus
subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape and
optical drives not supported. Maximum of 4 per PCI, maximum of 4 per system supported with
DIGITAL UNIX V3.2G or V4.0B; OpenVMS V6.2-1H3 or v7.1.
KZPAC-CA
PCI three-port SCSI RAID Controller with 4MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.
KZPAC-CB
PCI three-port SCSI RAID Controller with 8MB cache memory—Uses two PCI slots. Provides
three fast wide/single-ended connections. Allows RAID levels 0, 1 and 5. Includes RAID/Array
230/plus subsystem software and documentation kit. KFE70-AA EISA Bridge option required. Tape
and optical drives not supported. Maximum of four per PCI, maximum of four per system if third port
not used (otherwise maximum of three per PCI, three per system) supported with DIGITAL UNIX
V3.2G or V4.0B; OpenVMS V6.2-1H3 or V7.1. Order BN31K-0E or KZPAC-SB for third port
connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from
KZPSC-BA module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.
KZPSC-UB
Battery back-up for cache memory option for KZPAC or KZPSC controller.
MS100-BB
8 MB cache memory option; upgrades KZPAC-CA to KZPAC-CB, field installable only.
KZPSC-AA
PCI one-port SCSI RAID Controller—OpenVMS and DIGITAL UNIX support four per PCI,
maximum four per system (uses one PCI slot). KFE70-AA EISA Bridge option required. Provides one
fast/wide/single-ended connection. Allows RAID levels 0, 1, and 5. Tape drives are not supported.
KZPSC-BA
PCI SCSI RAID Controller with three ports—OpenVMS and DIGITAL UNIX support four per
PCI, maximum four per system (uses two PCI slots). KFE70-AA EISA Bridge option required.
Provides three Fast Wide/single-ended connections. Allows RAID levels 0,1, and 5. Tape drives not
supported. Order BN31K-0E or KZPAC-SB for third port connection.
BN31S-1E
1.5 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet (in front and rear locations) and BA661-AA. One required for each used port on
KZPSC-BA or KZPAC-CA/CB module.
BN31K-0E
Required for KZPSC-BA or KZPAC-CA/CB to use third port on module. Connects internally from
KZPSC-BA or KZPAC-CA/CB module to second PCI slot/bulkhead.
KZPAC-SB
SCSI cable/bulkhead assembly kit with two ports for KZPSC-BA or KZPAC-CA/CB, allows
connection of two third-port outputs using one PCI bulkhead slot.
BN31S-02
2.0 meter wide single-ended SCSI cable for connections from PCI RAID controller to BA660-AB
system cabinet and BA661-AA.
KZPSC-UB
Battery back-up for cache memory option for KZPAC or KZPSC controller.
MS100-AA†
16 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.
MS100-AB†
32 MB Cache memory option for KZPSC-AA/BA, maximum one per controller, field installable only.
KFPSA-AA
PCI DSSI Adapter (OpenVMS only)—Requires OpenVMS V6.2-1H2 or later; minimum
System Console Firmware Revision 3.09. Maximum twelve per PCI, 24 per system with OpenVMS
V6.2-1H3. (End node only) Note: KFPSA and KFMSB not supported on the same bus.
BC21Q-xx
External shielded cable (MR/MR connectors) Select required length—09, 16, 25, 50 ft
BC22Q-xx
External shielded cable (MR/PS connectors) Select required length—16, 25, 50 ft
† Requires AlphaServer 8400 minimum System Console Firmware Revision V3.2.2, OpenVMS V6.2-1H2 and DIGITAL UNIX V3.2D
or later operating system software.