background image

E-9

6

5

9

1

„

„

„

„

„

ST402-AG41-24V

‹

‹

‹

‹

‹

Serial Interface

RS-485(MPI) Interface (X)

  

 *2

*1 When providing power via the Seimens Co.'s Profibus connector, power cannot be connected

to the Device/PLC.

*2 The connector of the ST side is socket type.

Recommended Connector : Dsub 9 pin 

pin-type XM2A-0901

 <made by OMRON Corp.>

Recommended Cover : Dsub 9 pin cover XM2S-0913 <made by OMRON Corp.>

• When using an MPI interface, the Seimens Co.'s Profibus connector can be used.
• Use inch-type screws (#4-40UNC) as set screws.
• This unit is not equipped internally with termination resistance.  Attach termina-

tion resistance to the cable.

‹

‹

‹

‹

‹

Expansion Serial Interface

RS-422 Interface (Y)

Pin Connection

Pin No.

Signal

Signal Name

Direction

1

RDA

Receive data A

Input

2

RDB

Receive data B

Input

3

SDA

Send data A

Output

4

ERA

Enable receive A

Output

5

SG

Ground

-

6

CSB

Clear send B

Input

7

SDB

Send data B

Output

8

CSA

Clear send A

Input

9

ERB

Enable receive B

Output

    

*1

*1 The connector of the ST side is pin type.

Recommended Connector : Dsub 9 pin 

socket-type XM2D-0901

 <made by OMRON Corp.>

Recommended Cover : Dsub 9 pin cover XM2S-0913 <made by OMRON Corp.>

• Use inch-type screws (#4-40UNC) as set screws.
• This unit is not equipped internally with termination resistance.  Attach termina-

tion resistance to the cable.

Pin Connection

Pin No.

Signal

Signal Name

Direction

1

NC

No connection

-

2

NC

No connection

-

3

LINE(+)

Line (+)

In/Output

4

RTS

Request Send

Output

5

SG

Ground

-

6

5V

5V External Output

*1

Output

7

NC

No connection

-

8

LINE(-)

Line (-)

In/Output

9

NC

No connection

-

6

5

9

1

Содержание ST Series

Страница 1: ...sing the ST with transportation vehicles trains cars and ships di saster and crime prevention devices various types of safety equipment non life support related medical devices etc redundant and or failsafe system designs should be used to ensure the proper degree of reliability and safety After the ST backlight burns out unlike the ST s standby Mode the touch panel is still active If the operator...

Страница 2: ...ur eye flush your eye for 15 minutes with running water and contact a physician Unit Disposal When this unit is disposed of it should be done so according to your country s regulations for similar types of industrial waste Other Among backlight units there may be slight variations in illumination color however this does not effect the performance or quality of the ST unit General Safety Precaution...

Страница 3: ...efore turning it ON again If the ST is restarted too soon it may not start up correctly Due to the possibility of unexpected accidents be sure to back up the ST screen data regularly About the ST s Display Panel The ST s currently displayed data its voltage 1 and brightness setting each affect the intensity of Contouring i e when some parts of the screen are brighter than others creating a wavelik...

Страница 4: ...ount it on a vertical panel Also insure that the ST is mounted at least 100 mm away from any other adjacent structures or machine parts If these conditions are not met the heat generated by the ST s internal com ponents may cause it to fail to meet UL standards UL1604 Conditions of Acceptability and Handling Cautions 1 Power and input output wiring must be in accordance with Class I Division 2 wir...

Страница 5: ...Installation Guide 1 This Guide Installation Fasteners 4 InstallationGasket 1 Attached to the ST Unit Power Plug 1 Attached to the ST Unit F1 F1 F2 F2 F3 F3 F4 F4 F5 F5 F6 F6 Installation Guide Use the metallic label attached to the rear of the GP to identify your unit s revision code This code is at the bottom of the label to the right of REV In this example the asterisk mark is in the D position...

Страница 6: ...C Interface Y H RS 485 MPI Interface X I RS 422 Interface Y J Ethernet Connector X K RS 232C RS 422 Interface Y L Tool Connector TOOL 1 Part Names L Rear ST400 AG41 24V Bottom E F ST401 AG41 24V Bottom E G ST402 AG41 24V Bottom E I H C D A B Front F1 F1 F2 F2 F3 F3 F4 F4 F5 F5 F6 F6 ST403 AG41 24V Bottom J K E ...

Страница 7: ...ht Side Unit mm in F1 F1 F2 F2 F3 F3 F4 F4 F5 F5 F6 F6 2 Dimensions The ST unit dimensions are follows The following drawing shows the ST unit with installation fasteners 118 4 65 Top Front Right Side 104 4 09 5 0 20 41 1 61 Unit mm in 130 5 12 92 3 62 F1 F1 F2 F2 F3 F3 F4 F4 F5 F5 F6 F6 ...

Страница 8: ...Recommended Cover Dsub 9 pin cover XM2S 0913 made by OMRON Corp Use inch type screws 4 40UNC as set screws 3 Interfaces 5 9 1 6 5 9 1 6 Pin Connection Pin No Signal Signal Name Direction 1 CD Carrier detect Input 2 RD Receive data Input 3 SD Send data Output 4 ER Enable receive Output 5 SG Ground 6 DR Data set ready Input 7 RS Request send Output 8 CS Clear send Input 9 RI Ring indicate Input Pin ...

Страница 9: ... Pin No Signal Signal Name Direction 1 RDA Receive data A Input 2 RDB Receive data B Input 3 SDA Send data A Output 4 ERA Enable receive A Output 5 SG Ground 6 CSB Clear send B Input 7 SDB Send data B Output 8 CSA Clear send A Input 9 ERB Enable receive B Output 1 1 The connector of the ST side is pin type Recommended Connector Dsub 9 pin socket type XM2D 0901 made by OMRON Corp Recommended Cover ...

Страница 10: ... 1Transmission method is used by changing in software LED C ontents orange W hen the pow er supply is on LED lights up W hen sending or receiving LED blinks green W hen linking LED lights up Pin Connection Pin No Signal Signal Name Direction 1 CD RDA Carrier detect Receive data A Input Input 2 RD RDB Receive data Receive data B Input Input 3 SD SDA Send data Send data A Output Output 4 ER ERA Enab...

Страница 11: ...ime may have scratches or dirt on it and could have lost much of its dust and drip resistance Be sure to change the gasket periodically or when scratches or dirt become visible Be sure the gasket s seam is not inserted into any of the unit s cor ners only in the straight sections of the groove Inserting it into a corner may lead to its eventually tearing To ensure the installation gasket s maximum...

Страница 12: ...ews with too much force can damage the ST s plastic case The necessary torque is 0 5 N m Insertion Slots Right Left 2 Insert each fastener s hook into the installation fastener hole and tighten it with a screwdriver Installation fasteners are sold by your local ST distributor As shown in the following figure attach the Installation Fastener in the right position If not the ST unit may be drop out ...

Страница 13: ... is grounded If the power cord is pulled strongly the power plug may fall out When the FG terminal is connected be sure the wire is grounded Not grounding the ST unit will result in excess noise and vibration 5 Wiring WARNINGS The power cord should be equivalent to the specification shown above Be sure to twist the power cords together up to the power plug See illustration on next page Recommended...

Страница 14: ...ower plug from the ST unit 3 Remove the vinyl cover of each of the power cord s wires and insert each wire into the power plug s wire hole 4 Replace the power plug Use a flat screwdriver Size 0 6 x 3 5 to tighten the terminal block wire set screws The torque required to tighten these screws is 0 5 to 0 6 N m Do not solder the wire itself Rear of ST FG Terminal block wire set screws Power Plug ...

Страница 15: ... or input output signal lines Connect a surge absorber to handle power surges To reduce noise make the power cord as short as possible All ST Input and Output signal lines must be separated from all operating circuit power cords If this is not possible use a shielded cord and ground the shield 9 Maintenance and Periodic Inspection 8 Input Output Signal Line Cautions 7 Grounding Cautions 6 Power Su...

Страница 16: ... aware that the Digital Electronics Corporation shall not be held liable for any real or estimated damages or losses or third party claims resulting from the use of this product 2005 Digital Electronics Corporation ...

Отзывы: