Touch Panel Communication Program
FP-570T User's Manual
5-8
Touch the desigated positions, one after
the other.
"
"
"
"
"
Do not touch two points at the
same time.
Touch right above the designated
position.
By re-touching the points, the ac-
tual coordinates will redisplay.
Correction data will be calculated from
the difference between the actual and
the theoretical values.
Press the [Esc] key to terminate
the program. Press the [Y] key
after the message on the left is
shown, and the program will
terminate without saving any
calibration data. If the [N] key
is pressed, the system will return
to "calibration mode".
The actual value is shown on the display.
To enter "test mode", press the [Enter]
key.
This mode tests whether the calibration
has been processed correctly or not.
The calibration is confirmed as suc-
cessful if the locus shown on the
d i s p l a y m a t c h e s a s t o u c h e d .
Otherwise, return to the "calibration
mode" and redo the calibration by
touching the right blinking position.
Press the [Esc] key to return to
"calibration mode".
If the test result is OK, press the [Enter]
key. After the following message
appears, enter the name of the data file
and press the [Enter] key.
#
#
#
#
#
$
$
$
$
$
Enter the file name
When the data filename is speci-
fied from the parameter (-C=
[path]) during the execution of
CALIB.EXE, the program will
terminate without showing the
message on the left.