background image

Pag. 3 

Digit-KD instruction manual  

ENGLISH 

3.0.  BUTTONS AND INDICATORS 

Digit-KD

UNIT ON

TAMPER

FIRE

LOW BAT.

TEST

Buttons used to visualize or for 

running menu (*)

 

Forward  

Backward   

Button for arming in Night  

and Test-Control modes

 

Button to 

 by-pass zones

 

Optical  

indicators 

The buttons from 0 to 9 are used 

to digit access code 

 

Button for confirmation

 

Not used

 

Display 

LCD  

On the left of the keypad are present the following optical signalling with LED indications: 

 

UNIT ON   

   Control panel armed in Day and Night mode. 

 

 

 

-   Flashes quickly during exit time, then will light until the control panel is disarmed. 

 

-  If the  option 8 is  active  (see VISION instructions)  and  when  you  arm the control  panel 
 

there is an open line or the control panel's battery is low, the LED flashes slowly during 

 

exit time and then will light until the control panel is disarmed.   

 

 

-  If the option 8 is not active, the LED flashes slowly for a few seconds, then will go “off”.        
 

The control panel does not arm when this takes place. 

 

TAMPER  

  Tamper alarm 

 

-   In Maintenance mode, the LED will light for the time that the line remains unbalanced. 

 

-  In Programming mode, the LED will light during the keychain transmitters programming 
 

and flashes quickly during zone configuration (immediate/delayed). 

 

-   With the control  panel  armed in (Day  or Night  mode)  or  disarmed, if a tamper  alarm  is 
 

triggered the LED flashes slowly until the control panel is re-armed.   

 

FIRE   

   Fire alarm 

 

-   In Maintenance mode, this LED will light for the time that the line remains unbalanced.

 

 

-  In  Programming  mode,  the  LED  will  light  during  the  wireless  sensor  programming  and 
 

flashes quickly during the association of the zones to the Night group.   

 

-   With  the  control  panel  armed  in  (Day  or  Night  mode)  or  disarmed,  if  a  fire  alarm  is 
 

triggered the LED flashes slowly until the control panel is re-armed. 

 

 

LOW BAT.   

   Low battery 

 

-  In Maintenance mode, the LED will light to signal low battery of the control panel and of 
 

wireless sensor (every time the sensor triggers an alarm). 

 

-  In  programming  mode, the  LED  will  light during the  electronic  keys  or remote  keypads 
 

learning process and flashes quickly during the zone configuration (NC or balanced).  

 

-  With the control panel disarmed, armed and Test control mode, the LED flashes slowly  
 

to signal low battery of the control panel, and will flashes quickly to signal low battery of 

 

the wireless sensor. The signalling will remain active until the control panel is re-armed.   

 

TEST  

  Test-control 

 

-  In Maintenance mode, the LED flashes slowly.   

 

-  In Programming mode, the LED flashes quickly during all phases. 

 

-  The LED will light while by-passing zones and Test-control arming mode. 

 

 

Содержание VISION series

Страница 1: ...intenance status 6 6 0 Disarming 6 7 0 Total arming DAY mode 7 8 0 Partial arming NIGHT mode 8 9 0 Arming Test Control DAY mode 9 10 0 Arming Test Control NIGHT mode 10 11 0 By passing zones 11 12 0 T...

Страница 2: ...visualized Other characteristics Back light illumination of all buttons and display for approximately 30 seconds after a button is pressed In the case that more than one button is pressed the 30 secon...

Страница 3: ...ing zone configuration immediate delayed With the control panel armed in Day or Night mode or disarmed if a tamper alarm is triggered the LED flashes slowly until the control panel is re armed FIRE Fi...

Страница 4: ...t on the display indicate the zones in alarm or alarm memory In the example on the right zones 3 and 4 have been triggered and an alarm has taken place Buttons Are used to digit the access code Button...

Страница 5: ...s will appear on the display PROG KEY ch n 2 no MAINT OK PROG KEY ch n 1 si yes Press the button to memorize the code A beep is emitted from the control panel confirming that the code has been learned...

Страница 6: ...on the right MAINT OK 6 0 DISARMING With the control panel in Maintenance armed or Test Control status to disarm the control panel proceed as follows Digit one of any of the memorized codes example 1...

Страница 7: ...ancellation that takes place after approximately 40 seconds ON OK ON OK zone by p If a few zones are by passed during the exit time on the display will appear the message zone by p instead of delay Pr...

Страница 8: ...K ON OK Press the button to confirm The control panel emits one beep On the display the message on the right appears The writing ON and the LED UNIT ON will flash quickly After a few seconds the writi...

Страница 9: ...y Keep in mind that only the alarm with the highest priority level is visualized entirely on the display and remains in memory until the control panel is re armed To verify if there have been other al...

Страница 10: ...e Night group during the exit time on the display the message zone by p instead of delay will appear To verify the zones by passed or associated to the Night group proceed as indicated on the points 3...

Страница 11: ...forth BY PASS zone 2 no To pass to the next zone press the button A message regarding the status of the second zone will appear on the display To by pass the zone press the button BY PASS zone 2 si y...

Страница 12: ...e instructions of the control panel installed 12 0 TAMPER KEYPAD Even if the control panel is armed with the mechanical key the tamper of the remote keypad is always in function ATTENTION 13 0 TECHNIC...