10.0. ARMING TEST-CONTROL  

(NIGHT mode) 

With the control panel disarmed (OFF), proceed as follows: 

 

 

*** 

 

TEST              
  OK  

Before  the  writing  “delay”  appears,  press 
the  button      .  The  writing  “TEST”  will       
appear and it will flash quickly.  
After a few seconds the writing “delay” that 
indicates a 60 seconds exit time will appear.  
Press again the button       .  
On the  display a moon symbol      that flashes 
quickly 
will appear.

 

TEST              
  OK  

    delay

 

Violation  of  one  or  more  zones  provokes the  appea-
rance  of  a flashing  message  on the display.  Keep in 
mind that only the alarm with the highest priority level 
is  visualized  entirely  on  the  display  and  remains  in 
memory until the control panel is newly armed.  
To  verify  if  there  have  been  other  alarm  events,      
access the menu by pressing the button "FORWARD". 
Next to  each  zone that has triggered  an  alarm  a  dot 
will appear that flashes slowly (see on the right). 

 

 

 "zone 3" has triggered an alarm 

TEST              
  OK  

If a few zones are by-passed or associated 
to  the Night group, during the  exit  time  on 
the  display  the  message  “zone  by-p”       
instead of “delay” will appear. To verify the 
zones  by-passed  or  associated  to  the 
Night  group,  proceed  as  indicated  on  the 
points 3) and 4) of the paragraph  7.0.

 

TEST                              
  OK   

zone by -p

 

TEST              
  hold-up    wire  

TEST              
  OK  

1      2 

3      4 

If while arming there are zones triggered or 
unbalanced not by-passed and not associated to 
the  Night  group,  or  control  panel  has  low 
battery, the  writing “TEST”  and the symbol 
of the moon     on the display and the LED 
ON” will flash slowly during the exit time.  
Furthermore, the message “zone in alarm” or “battery centr.” will appear.

 

 

Digit  any  one  of  the  memorized 
codes    (example  1,  2  and  3).  On 
the display 3 asterisks will appear. 

 

Press the button       to confirm.  
The  control  panel  emits  one beep.  On  the 
display the message on the right appears.  
The  writing  “ON”  and  the  LED  “UNIT ON” 
will  flash quickly.  The  LED  “TEST”  will 
light and remains so until the control panel is disarmed. 

 

ON 

        

  OK 

At  the  end  of  the  exit  time,  the  writing  “delay” 
will disappear and the writing “ON”, the symbol 
of the  moon    and the LED “UNIT ON” from 
flashing quickly will become fixed. The control 
panel is armed in Test-Control Night mode. 

TEST                                  

  

zone  in  alar m 

 

                  delay

 

Содержание VISION series

Страница 1: ...intenance status 6 6 0 Disarming 6 7 0 Total arming DAY mode 7 8 0 Partial arming NIGHT mode 8 9 0 Arming Test Control DAY mode 9 10 0 Arming Test Control NIGHT mode 10 11 0 By passing zones 11 12 0 T...

Страница 2: ...visualized Other characteristics Back light illumination of all buttons and display for approximately 30 seconds after a button is pressed In the case that more than one button is pressed the 30 secon...

Страница 3: ...ing zone configuration immediate delayed With the control panel armed in Day or Night mode or disarmed if a tamper alarm is triggered the LED flashes slowly until the control panel is re armed FIRE Fi...

Страница 4: ...t on the display indicate the zones in alarm or alarm memory In the example on the right zones 3 and 4 have been triggered and an alarm has taken place Buttons Are used to digit the access code Button...

Страница 5: ...s will appear on the display PROG KEY ch n 2 no MAINT OK PROG KEY ch n 1 si yes Press the button to memorize the code A beep is emitted from the control panel confirming that the code has been learned...

Страница 6: ...on the right MAINT OK 6 0 DISARMING With the control panel in Maintenance armed or Test Control status to disarm the control panel proceed as follows Digit one of any of the memorized codes example 1...

Страница 7: ...ancellation that takes place after approximately 40 seconds ON OK ON OK zone by p If a few zones are by passed during the exit time on the display will appear the message zone by p instead of delay Pr...

Страница 8: ...K ON OK Press the button to confirm The control panel emits one beep On the display the message on the right appears The writing ON and the LED UNIT ON will flash quickly After a few seconds the writi...

Страница 9: ...y Keep in mind that only the alarm with the highest priority level is visualized entirely on the display and remains in memory until the control panel is re armed To verify if there have been other al...

Страница 10: ...e Night group during the exit time on the display the message zone by p instead of delay will appear To verify the zones by passed or associated to the Night group proceed as indicated on the points 3...

Страница 11: ...forth BY PASS zone 2 no To pass to the next zone press the button A message regarding the status of the second zone will appear on the display To by pass the zone press the button BY PASS zone 2 si y...

Страница 12: ...e instructions of the control panel installed 12 0 TAMPER KEYPAD Even if the control panel is armed with the mechanical key the tamper of the remote keypad is always in function ATTENTION 13 0 TECHNIC...

Отзывы: