background image

 

9

 

 

Figure 10 

 

WIRING 
 

Attn: Do not turn on the DNG-2300 until you have completed wiring the transducers as 
recommended in this manual.

 

 
Route the wiring so that it cannot be pinched, cut, tripped over, or damaged in any way. Connect the 
wires to the transducer using the female "quick connect" tabs furnished. Crimp or solder the wire to 
the tab. 
 
For lengths of less than 60 feet, use 18-gauge "zip cord" wire. Use 14-16 gauge heavy-duty speaker 
cable (sold at audio stores) for longer runs that have impedance of less than 3 ohms. Use the 
conductor that is silver o

|

r has markings on the insulator as the negative wire. 

 
Attn:    Each generator output is designed to be separate and isolated. Do not cross output 
wiring or allow any wiring to be connected to the building's metal or earth ground.

 

 
OUTPUT ADJUSTMENT 
 
The actual noise level required to mask speech is dependent on the square footage and composition of 
the surface, the ambient noise, and the general loudness of the conversation to be protected. Under most 
situations, the required output level will produce a low to moderate noise level in the target area with 
which one can talk comfortably. The actual level required under specific situations can be measured with 
optional probe microphone DNG-MIC or optional probe stethoscope DNG-STET.  
 

Transducers 

1.

 

Ensure that all the connections are made and the power is on. 

2.

 

Place the testing stethoscope DNG-STET on a surface in the protected room.  

3.

 

Tune the channel which controls the transducers. If both channels are used by transducers, tune 
both of them. First decrease the output level to the minimal position. 

4.

 

Increase output level until the LOOPBACK indicator shows the middle reading – the red light 
should be on the 10

th

 segment of the bargraph. 

5.

 

Put the DNG-STET on other surfaces in the room and check that the LOOPBACK reading is 
not less than 10. Increase the level if necessary. Probe all the surfaces in the protected room – 
walls, windows, ceilings, etc.  

  

Speakers 

1.

 

Ensure that all the connections are made and the power is on. 

2.

 

Place the probe microphone DNG-MIC where conversations are conducted – on/under/by a table 
or other places.  

3.

 

Tune the channel which controls the speakers. First decrease the output level to the minimal 

Содержание DNG-2300

Страница 1: ...USER MANUAL DNG 2300...

Страница 2: ...rt of the noise gets inside a room This does not force people to speak louder The TRN 2000 transducer can be supplied with adapters for mounting on walls ceilings windows etc The speaker OMS 2000 can...

Страница 3: ...ystem Therefore prior to the installation of the DNG 2300 it is recommended to perform thorough sweep accompanied by a physical search When performing detection and location the following tools can be...

Страница 4: ...onstruction or remodeling where sensitive points in the structure can be protected with transducers built into the building s structure If this is not possible the transducers can be placed directly o...

Страница 5: ...Screw Adapter into the transducer 2 Drill a 1 8 pilot hole in the wall 3 Screw the transducer clockwise into the pilot hole until it is flush to the surface DO NOT TIGHTEN EXCESSIVELY Figure 3 If the...

Страница 6: ...discard the double stick tape and use a small amount of clear silicone exterior caulking compound Place a small thin layer across the disk and press firmly and evenly to minimize air bubbles This met...

Страница 7: ...le figure 7 Figure 7 Closets Crawl Spaces Place the speaker centered in the space halfway between the floor and ceiling figure 7 SYSTEM SETUP The DNG 2300 combats the problem of acoustic leakage by in...

Страница 8: ...very little space between the tile and the top of the ceiling Similarly to the transducers care should taken if the speaker levels are mixed to ensure that proper volume is being achieved to all the...

Страница 9: ...e required output level will produce a low to moderate noise level in the target area with which one can talk comfortably The actual level required under specific situations can be measured with optio...

Страница 10: ...that area and leave the DNG 2300 off Carefully probe any surface from the inside or outside that is connected to the target area including windows doors plumbing air ducts etc The identification of t...

Страница 11: ...an 3 ohms to the output Avoid areas with high moisture Do not drop Provide adequate ventilation around the cabinet Avoid extreme temperature exposure below 22F 30C or above 122F 50C There are no servi...