INTRODUCTION

  

 

ACOUSTIC EAVESDROPPING 
 
Thank you very much for purchasing the DNG-2300 digital noise generator. The DNG-2300 is 
designed to prevent listening though devices that cannot be detected by conventional 
countermeasures and installed around the perimeter of a room – wired wall microphones, contact 
microphones, AC outlet transmitters and window systems based on the reflection of 
laser/infrared/microwave beams. It is an excellent addition to high level countermeasures. 
 
It is well-known that sound distributes though walls, doors, windows and other constructions. In 
some materials sound travels even better than through air. For example, water is a good conductor 
and a heating system can pass a conversation out of a room. Eavesdroppers take advantage of this 
with the use of contact microphones. These microphones pick up the vibrations from the air ducts, 
plumbing, structures, walls, windows, doors, floors, ceilings and more. The microphones may not 
be in the same room as the conversation, but may be several floors or rooms away attached to a 
pipe or other fixture.  
 
The DNG-2300 can render these devices useless. It produces non-filterable acoustic noise which is 
transferred to constructions by transducers and speakers. REI’s TRN-2000 is the recommended 
transducer for use with the DNG-2300. It has optimal power parameters and can be set on different 
types of surfaces. The TRN-2000 injects most of its power into surfaces while only a tiny part of 
the noise gets inside a room. This does not force people to speak louder. The TRN-2000 transducer 
can be supplied with adapters for mounting on walls, ceilings, windows, etc. 
The speaker OMS-2000 can also be used with the DNG-2300. It does not inject the noise into the 
surfaces but radiates it into surrounding space. The OMS-2000 is usually used in air ducts, ceiling 
tiles, etc.  
 
TRULY RANDOM NOISE 
 
The DNG-2300 consists of 3 independent white noise digital generators. “White” means that the 
noise is fully random and is equally distributed along the voice spectrum. This distribution 
provides complete resistance against the filtering of a conversation. Another feature of white noise 
is its unpredictability i.e. there is no method to wipe it out from a recorded conversation.  
 
VOICE MASKING 
 
Men’s and women’s voices consist of lots of frequencies simultaneously produced during speech. 
These frequencies lie between 100 Hz and 6000 Hz. Listening devices usually have a narrower 
range mostly because of size limitations, the scheme of the device and battery time. The DNG-
2300 has a range of 250-5000 Hz which is optimal to cover all types of voices and suppress all 
listening devices.  
 
OPERATION 
 
The DNG-2300 uses a combination of transducers and speakers placed strategically throughout a 
target area to create a blanket of masking noise that covers private conversations from 
eavesdropping. Each transducer utilizes adapters for mounting to a variety of surfaces such as 
walls, windows, ductworks, plumbing, etc. The three separate channels allow the user to tailor the 
noise for separate materials, allowing greater flexibility and increased protection.  
 
 

Содержание DNG-2300

Страница 1: ...USER MANUAL DNG 2300...

Страница 2: ...rt of the noise gets inside a room This does not force people to speak louder The TRN 2000 transducer can be supplied with adapters for mounting on walls ceilings windows etc The speaker OMS 2000 can...

Страница 3: ...ystem Therefore prior to the installation of the DNG 2300 it is recommended to perform thorough sweep accompanied by a physical search When performing detection and location the following tools can be...

Страница 4: ...onstruction or remodeling where sensitive points in the structure can be protected with transducers built into the building s structure If this is not possible the transducers can be placed directly o...

Страница 5: ...Screw Adapter into the transducer 2 Drill a 1 8 pilot hole in the wall 3 Screw the transducer clockwise into the pilot hole until it is flush to the surface DO NOT TIGHTEN EXCESSIVELY Figure 3 If the...

Страница 6: ...discard the double stick tape and use a small amount of clear silicone exterior caulking compound Place a small thin layer across the disk and press firmly and evenly to minimize air bubbles This met...

Страница 7: ...le figure 7 Figure 7 Closets Crawl Spaces Place the speaker centered in the space halfway between the floor and ceiling figure 7 SYSTEM SETUP The DNG 2300 combats the problem of acoustic leakage by in...

Страница 8: ...very little space between the tile and the top of the ceiling Similarly to the transducers care should taken if the speaker levels are mixed to ensure that proper volume is being achieved to all the...

Страница 9: ...e required output level will produce a low to moderate noise level in the target area with which one can talk comfortably The actual level required under specific situations can be measured with optio...

Страница 10: ...that area and leave the DNG 2300 off Carefully probe any surface from the inside or outside that is connected to the target area including windows doors plumbing air ducts etc The identification of t...

Страница 11: ...an 3 ohms to the output Avoid areas with high moisture Do not drop Provide adequate ventilation around the cabinet Avoid extreme temperature exposure below 22F 30C or above 122F 50C There are no servi...

Отзывы: