IPP-S Installation guide                                                  Digipower Inc. 

 

23 

 

Radius 

 

System supports the Remote Authentication Dial-in User Service protocol (RADIUS). It provides a 

centralized network protocol to enable remote authentication and authorization. 

Log 

 

Export: 

Export events and data log in text format. Set the date to mail kWh usage 
information. 

Содержание IPP-S Series

Страница 1: ...Digipower Inc 2017 Digipower Inc 2017 5 5 Intelligent Power Panel with Switch Installation Guide...

Страница 2: ...llation Diagram 4 Digital Input Wiring Diagram 5 Digital Output Wiring Diagram 5 Installation Notes 5 Operation 6 Normal Mode 6 Brightness adjusting 6 Show IP address 7 1P3W 3P3W 3P4W setting 7 Test M...

Страница 3: ...IPP S Installation guide Digipower Inc 1 Installation Diagram Faceplate Functional Description...

Страница 4: ...ference point with two wattmeter measurement measure the voltage between L1 N with current L1 L2 N with current L2 C1 detects L1 current on L1 N C2 detects L2 current on L2 N The rest C3 C4 or C5 C6 o...

Страница 5: ...rent in L3 to get 3P3W power consumption The figure shown C1 detects L1 current the voltage is L1 L2 The figure shown C2 detects L2 current the voltage is L3 L1 The figure shown C3 detects L3 current...

Страница 6: ...current in L2 and L3 N with current in L3 to get 3P4W power consumption The figure shown C1 detects L1 current the voltage is L1 N The figure shown C2 detects L2 current the voltage is L2 N The figure...

Страница 7: ...ent is 400V 2 Check that the voltage and current phases are connected properly 3 Measuring the diameter of the conductor the bare wire with the insulation removed and selecting the suitable size of de...

Страница 8: ...and IP address 1 5 Pressed 3 seconds simultaneously enter 1P3W 3P3W 3P4W setting Mode 1 6 Pressed 3 seconds simultaneously enter Test Mode 1 7 Pressed 3 seconds simultaneously enter Load setting Mode...

Страница 9: ...ode 2 4 Pressed 3 seconds to save then return to Normal Mode 1P3W 3P3W 3P4W setting In this mode select 1P3W 3P3W 3P4W in accordance with wires installation Item Key Description 3 1 or Select 1P3W 3P3...

Страница 10: ...loop 5 5 Pressed 3 seconds to save then return to Normal Mode Meter ID setting In this mode set Meter ID from 1 to 99 Item Key Description 6 1 or Select Meter ID 6 2 Select 1st digit or 2nd digit 6 3...

Страница 11: ...se Wire 1P2W 1P3W 3P3W 3P4W Module 12 power monitoring modules with 1P2W Communication Display 5 digits 7 segments display power information and IP address in turn 1 digit 7 segments display load numb...

Страница 12: ...ature 20 60 Celsius degree Operation Humidity 20 95 RH Size 192x308x50 mm Weight 1 4 kg Warranty 2 years Certification FCC CE Measurement CT inner diameter mm 25 16 10 Rated Current 200 A 120 A 60 A R...

Страница 13: ...e default setting for the way to get IP address is DHCP If PDU cannot get the IP from DHCP server the IP address will stay at 192 168 0 216 Default ID snmp Default Password 1234 After login to web use...

Страница 14: ...IPP S Installation guide Digipower Inc 12 Information Overview Display Power information summary and DI DO status...

Страница 15: ...IPP S Installation guide Digipower Inc 13 Chart Display All Power Information in trend System Display System Network and SNMP Information Event Log...

Страница 16: ...contact output to on or off DO Select specifying DO 1 DO 4 or all DOs Status Display the status of each DO Task Show DO command execution status Free means that no command is currently executed Busy r...

Страница 17: ...DO 1 4 DO Action Select Close On or Open Off Date Click Once if the action is executed only once then input date Format yyyy mm dd Click Every if the action is executed periodically then select Monday...

Страница 18: ...reshold Configuration The hi lo alarm setting for Temperature and Humidity DI Configuration Enter the name of Digital Input DO Configuration Enter the name of Digital Output Circuit Threshold Configur...

Страница 19: ...umidity Overrun or Humidity Underrun and then select Occurs or Removed Trap First enter the object code the options of Value are Ignore Integer and String then enter Integer or String finally enter Tr...

Страница 20: ...hh mm hh mm and On Peak contracted power in KW Date Select date period Add to Top Add the demand schedule into the top of list Add to Bottom Add the demand schedule into the bottom of list Save Save...

Страница 21: ...KW Green curve Estimated accumulation of KW in the end of demand period Red curve The above estimated value higher than setpoint The equation of demand controller as below EPD TPD TPD 100 D Outputs 1...

Страница 22: ...wifi dongle 2 Set Wireless Configuration in the Network Information 3 Restart IPP after the Wireless Configuration setting is completed Note The default setting for the way to get IP address is DHCP...

Страница 23: ...onfigure PDU Default ID is snmp password is 1234 Access Information Management Configuration Power user Monitor PDU control the specified outlets No permission to configure PDU Default Password passwo...

Страница 24: ...IPP S Installation guide Digipower Inc 22 SNMP Simple Network Management Protocols Configuration Support SNMPv1 v2 and v3 Time Time by NTP or Manually for Schedule and Log record...

Страница 25: ...pports the Remote Authentication Dial in User Service protocol RADIUS It provides a centralized network protocol to enable remote authentication and authorization Log Export Export events and data log...

Страница 26: ...ecified event System Configuration files export and Import Firmware Upgrade Reset Functions System Export to backup system configuration Import system configuration from backup file Reset System Resta...

Страница 27: ...on your mobile phone to open DGP IPP Secure app 2 Click icon on Device List to enter Modify page 3 Modify the ID consistent with APP ID on web page 4 Enter preferred NAME and Password or Password keep...

Отзывы: