![Digimerge DPZ16TO27 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/digimerge/dpz16to27/dpz16to27_instruction-manual_2497705010.webp)
Speed Dome Camera Instruction Manual
10/49
DIP Switch Setup
Before installing the camera, set up the DIP switch to configure the camera ID and the
communication protocol.
Camera ID Setup
ON
ON
1
2
3
4
5
6
7
8
z
ID numbers of cameras are set up with binary numbers.
See the examples shown below.
Pin
1
2
3
4
5
6
7
8
Binary
Value
1 2 4 8 16 32 64
128
ex)
ID=5
on off on off off off off off
ex)
ID=10
off on off on off off off off
z
The camera ID range is “1~255”.
Camera ID must not be
“0”!
z
The factory default of the camera ID is “1”.
z
Match the camera ID with the Cam ID setting of your DVR
or Controller to control the camera.
z
If you are connecting a single camera to a controller,
terminate the camera. When connecting more than one
camera to a single controller, terminate the last camera on
the communication line. The last camera means the camera
farthest in cable length from the controller.
z
Note that the total length of the communication cable
between a controller and the camera(s) on the same
communication line must be less than 1.2Km.
INSTALLATION
2