IQOYA *CALL - IQOYA *CALL/LE
User Manual v0.99
GPI optocoupler specifications
Minimum current imin to switch GPI
1 mA
Maximum current imax supported
60 mA
Maximum voltage V
K
supported
11 V
DC
General Purpose Outputs (GPOs)
The IQOYA *CALL GPOs are optoisolated SPDT type relays (Single Pole, Double Throw).
Each GPO features 3 pins:
●
COM : Common
●
N.C. : normally closed
●
N.O. : normally open
According to the status applied to the GPO, pin N.C. is connected to pin COM, or pin N.O. is connected to pin
COM.
GPO relay specifications
Maximum power switching capability
60 W/62.5 VA
Maximum switching current
5 A
DC
Maximum carrying current
2 A
DC
Maximum switching voltage*
220 VDC /0.24A60 W
250 VAC /0.2562.5 VAC
125 VAC /0.5A62.5 VAC
30 VDC /2 A60 W
Typical life expectancy (switching max power)
10
6
operations
*Note: The maximum voltage makes it possible to control devices (up to 60 W. max) directly through the power
outlet.