Trillium Lane Labs Plug-ins Guide
70
Export Button
The Export button exports all of the informa-
tion displayed in the two browsers to the clip-
board as tab delimited text. It can then be pasted
into any text or spreadsheet application.
View Time Menu
The View Time menu lets you select the way in
which timing information is displayed, in either
minutes and seconds format, or in samples for-
mat. This affects the timecode display in both
the data browsers and the Offset field.
Offset Field
The Offset field offsets the values displayed in
both the browsers by the value entered. This is
useful for historical metering but the session
was started from a point other than the begin-
ning. The Enter key must be used after a new off-
set is typed for it to become active. The informa-
tion shown in the browsers is updated
immediately when the new Offset is entered.
For example, if the session was started from the
point 1:03.901 (1 minute 3.901 seconds), this
value should be entered into the Offset to en-
sure the timecode displayed in both of the
browsers matches that of the Pro Tools session.
Clip Field
The Clip field can be used to set the clip thresh-
old at a lower point. For example, if a session
must not exceed –10 dB, the Clip field can be set
to –10 dB and TL MasterMeter will treat that as
the clip threshold for both signal and oversam-
pled clip events. When the Clip field is set to a
non-zero value, the Min and Max values of the
Signal Clip browser are used to indicate the clip
range.