700HS service manual
-
4 –
servicing
4
-
52 Issue 2 06/2020
Calibration of touch screen
-
15'' version
If the touch points on the screen are not matching with where you are touching the screen, the screen may
need to be calibrated.
With the machine switched on, exit to Windows® level
On the desk top, click on the icon
‘
eGalaxTouch
’
On the eGalaxTouch : USB
Controller screen select the Tools
tab
The required calibration can be
selected
When calibration is complete, a
Draw test feature can be used to
check the screen accuracy
Touch each point that
appear in the red circle
within the time allowed for
the number of calibration
points selected
When calibration is
complete, touch OK to
finish
Содержание HI-700HS
Страница 1: ...HI 700HS service manual Issue 2 06 2020 HI 700HS Service manual...
Страница 98: ...HI 700HS service manual 2 component parts 2 64 Issue 1 02 2020 HS blow applicator Pneumatics...
Страница 238: ...HI 700HS service manual 4 servicing 4 129 Issue 2 06 2020 Side labeller applicator Pneumatics...
Страница 270: ...Main electrical cabinet P5 2...
Страница 271: ...Main electrical cabinet P5 3...
Страница 272: ...Main electrical cabinet display enclosure P5 4...
Страница 273: ...Single Servo indexer contol box P5 5...
Страница 274: ...Single Servo indexer control box P5 6...
Страница 275: ...Triple Servo indexer control box P5 7...
Страница 276: ...Triple servo indexer control box P5 8...
Страница 277: ......
Страница 278: ......
Страница 279: ......
Страница 280: ......
Страница 281: ...Low voltage 24v power lift P5 13...
Страница 282: ...240v power lift P5 14...
Страница 283: ...240v power lift P5 15...
Страница 288: ...P5 20 15 touch screen assembly not HS style...
Страница 289: ......