26
Weight and Measures Specification :
The Span Switch must be on to enter this mode. To
enter this mode, press and hold the Re-zero Key, while holding the Re-zero press 1, 4, 2,
then release the Re-zero key.
Sequence: [Re-zero] [1] [4] [2].
Spec No.
Bit 3
Bit 2
Bit 1
Bit 0
Display Resolution
0
00 = 1/3000
01 = 1/6000
10 = 1/12000
11 = 1/15000
Not used
0 = single range
1 = multi range
Weight Decimal Point Position
1 Display
0 = decimal pt
1 = comma
000 = 00000
001 = 0000.0
010 = 000.00
011 = 00.000
100 = 0.0000
Minimum Display
2 Not
used
000 = 1
001 = 2
010 = 5
011 = 10
100 = not used
101 = not used
3
Change Units
(lb.
↔
↔
↔
↔
kg
↔
↔
↔
↔
g
↔
↔
↔
↔
oz)
0 = no
1 = yes
"
"
"
"
new spec ver1.19
Not used
IR Mode
Protected By
Span Switch
0 = no
1 = yes
Change Units
(lb.
↔
kg)
0 = no
1 = yes
Set-Point Buzzer Range
(Outside Min & Max)
/Print Range(RS-232)
4
00 =
>
net 5d & gross 21d
01 =
> net 1d
10 =
> net 19d
11 =
>
net 20d
Auto Tare Clear
Range
0 = gross over
20d and net
over 4d
1 = gross over
0d and net
over 1d
Not used
5
Not used
Not used
Not used
Not used
6
Not used
Not used
Not used
Not used
7
Not used
Not used
Not used
Not used
8
Not used
Not used
Not used
Not used
9
Not used
Not used
Not used
Not used
All manuals and user guides at all-guides.com
Содержание DS-470
Страница 2: ...All manuals and user guides at all guides com ...
Страница 8: ...5 3 4 RS 232 Cable Installation All manuals and user guides at all guides com ...
Страница 9: ...6 3 5 1 DS 470 SS Unlocking Procedure All manuals and user guides at all guides com ...
Страница 33: ...30 7 8 Shop Notes All manuals and user guides at all guides com ...