15
6.1.4. COMMUNICATION METHOD
By specification setting (Spec 59 bit 2 & 3), the communication method may be
selected from Stream (continuous output), Manual (output by pressing
[
½
½
½
½
]
key,
and Command (output by command from external device).
6.1.4.1. STREAM
Data is transmitted to external device continuously.
DATA STREAM:
The SPEC to select whether weight stable status or not by specification setting
(Spec 53 bit 3).
Example: without stable flag
STX
Header
Gross Weight
CR
Header
Net Weight
CR
1 1 5 1
1 5 1
Header
Tare Weight
CR
Header Set-point Status
CR
LF
1 5 1
1 2 1
1
Example: with stable flag
STX
Stable
Header
Gross Weight
CR
Header
Net Weight
CR
1 1 1
5
1 1
5 1
Header
Tare Weight
CR
Header Set-point Status
CR
LF
1 5 1
1 2 1
1
Weight Stable Status:
Status Data
Stable
SOH (01 H)
Un-stable
NUL (00 H)
Set-point status
Status Data
Set-point is not programmed
B
1
1
Weight < Set-point 1
B
1
1
Set-point 1 < Weight <Set-point
B
0
1
Set-point 2 < Weight
B
0
0
The Data is transmitted when the machine is in operation mode. While entering
numeric data, the transmission would be stopped.
All manuals and user guides at all-guides.com
Содержание DS-470
Страница 2: ...All manuals and user guides at all guides com ...
Страница 8: ...5 3 4 RS 232 Cable Installation All manuals and user guides at all guides com ...
Страница 9: ...6 3 5 1 DS 470 SS Unlocking Procedure All manuals and user guides at all guides com ...
Страница 33: ...30 7 8 Shop Notes All manuals and user guides at all guides com ...