"Digi II" Series Heater Installation & Operation Instructions
DIAGRAM 5
IMPORTANT: A neutral wire is required to operate the control. The electrical installation must be
made by a licensed electrician in accordance with local regulations.
Use 14-2 with ground wire for the fan and light.
CAUTION-USE SUPPLY WIRES SUITABLE FOR AT LEAST 90°C (194°F) USE COPPER WIRE
ONLY.
For use input Power input 208-240V Ac 1ph 60Cyc Power input 208-240V Ac 3ph 60Cyc
with kw Copper wire size Copper wire size
heater to heater to heater
1714-450-1705 4,5 2xAWG
10
+N+Gr
3xAWG
12
+N+Gr
1714-600-1705 6,0 2xAWG
8
+N+Gr
3xAWG
12
+N+Gr
1714-800-1705 8,0 2xAWG
8
+N+Gr
3xAWG
10
+N+Gr
1 2 3 4 5 6
Gr
Gr N
T1 T2 T3
Gr
Gr
N
T1 T2
Heater
The electrical installation
must be made by a licensed
electrician
in
accordance
with local regulations.
CAUTION-USE SUPPLY WIRES
SUITABLE FOR AT LEAST 90
O
C
(194
O
F)USE COPPER WIRE ONLY.
1714-450-1705 4,5 2xAWG
10
+ N+Gr
3xAWG
12
+N+Gr
1714-600-1705 6,0 2xAWG 8 +N+Gr
3xAWG
12
+N+Gr
1714-800-1705 8,0 2xAWG 8 +N+Gr
3xAWG
10
+N+Gr
240V 208V
240V 208V
354 SKSO 25 F
3 ph
1 ph
1 2 3 4 5 6
kW
SEPC 95
2670W
SEPC 94
2000W
SEPC 93
1500W
Heater
Input
Heating elements
208V or 240V
Type
1,2,3
4,5
6,0
8,0
1,2,3
1,2,3
1714 - 450 - 1705
1714 - 600 - 1705
1714 - 800 - 1705
B
F
Cont
L N Light Fan
1 2 1 2 3 4 5 1 2 3 4 5
J3 A B
1 2 3 4 5 6 N
Light Fan
Sensor
Control panel
1601-11
Gr
N
N
K3
K1
K2
P1
P3
1
2
3
A2
A1
1
2
3
7
5
4
6
8
P2