Digi Digi II 4.5 Скачать руководство пользователя страница 4

"Digi II" Series Heater Installation & Operation Instructions

DIAGRAM 2

DIAGRAM 3

DIAGRAM 4

Floor Area

Ceiling 

Height

Volume

Cu. Ft.

Ceiling 

Height

Volume 

Cu. Ft.

1

208

21.6

2 #10 AWG + 

N+Gr

1

240

18.8

2 #10 AWG + 

N+Gr

3

208

12.5

2 #12 AWG + 

N+Gr

3

240

10.8

2 #12 AWG + 

N+Gr

1

208

28.8

2 #8 AWG + 

N+Gr

1

240

25

2 #8 AWG + 

N+Gr

3

208

16.7

3 #12 AWG + 

N+Gr

3

240

14.4

3 #12 AWG + 

N+Gr

1

208

38.5

2 #8 AWG + 

N+Gr

1

240

33.3

2 #8 AWG + 

N+Gr

3

208

22.2

3 #10 AWG + 

N+Gr

3

240

19.2

3 #10 AWG + 

N+Gr

250

96"

425

Digi II 8.0

1714-800-1705

8.0

40 sq. ft.

75"

100

96"

210

Digi II 6.0

1714-600-1705

6.0

28 sq. ft.

75"

175

96"

310

Digi II 4.5

1714-450-1705

4.5

16 sq. ft.

75"

PHASE

VAC

AMPS

WIRE 

SUPPLY TO 

HEATER

HEATER MODEL 

Product Number

kW

MINIMUM ROOM

MAXIMUM ROOM

Содержание Digi II 4.5

Страница 1: ...l and benches Replace wood surfaces which show any signs of deterioration The heater gets extremely hot during operation and should not be touched or burns may result Minors should be adequately super...

Страница 2: ...M 1 MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL Screws Use the long screws in the upper holes of the mounting bracket 11 57 8 11 B Screws Table 1 K A D High Limit Control 6...

Страница 3: ...and reinstall reusable rocks Follow the directions below for placement and the 1 Put smaller rocks in first around the outer perimeter of the heating chamber 2 Completely fill all four sections front...

Страница 4: ...AWG N Gr 1 208 28 8 2 8AWG N Gr 1 240 25 2 8AWG N Gr 3 208 16 7 3 12 AWG N Gr 3 240 14 4 3 12 AWG N Gr 1 208 38 5 2 8AWG N Gr 1 240 33 3 2 8AWG N Gr 3 208 22 2 3 10 AWG N Gr 3 240 19 2 3 10 AWG N Gr 2...

Страница 5: ...e maximum control wire length would be 90ft The sensor should be mounted over the heater 2 from the ceiling and connected to the circuit board on terminals 2 and 3 See Diagram 1 Control Overview Alarm...

Страница 6: ...r 1714 800 1705 8 0 2xAWG 8 N Gr 3xAWG 10 N Gr 1 2 3 4 5 6 Gr Gr N T1 T2 T3 Gr Gr N T1 T2 Heater The electrical installation must be made by a licensed electrician in accordance with local regulations...

Страница 7: ...ess PROG OK button and hold down for approx 3 seconds until the following appears in the display MENU 1 TIME 12 00 Setting the Clock Press the up arrow and hold down The minutes and hours will begin t...

Страница 8: ...ext will display MENU 5 CLOCK 24 h Using the arrow keys select a 12 or 24 hour clock If a 12 hour clock is selected AM or PM will appear in the display after the time Press PROG OK to save the setting...

Страница 9: ...ing will appear in the display start time sauna length and temperature 17 30 01 00 The maximum the timer will allow the heater to operate is 60 minutes 90C Press Time Delay button and the hours and mi...

Страница 10: ...Sauna depending on what delay mode is selected 15 00 is the current time and 17 30 is the time the room is ready to enter Daily Operations of Memory User buttons Press ON OFF and the greeting appears...

Страница 11: ...ress when completely dry and perspiration has stopped Some sauna bathers enjoy the soothing effect of steam by splashing water on the heated sauna rocks Use only one dipper full approx cup at a time a...

Страница 12: ...4 framing 1 2 wallboard fiberglass insulation 1 2 wallboard T G soft wood foil vapor barrier HEATER SCREEN GUARD RAIL DIAGRAM 7 VENTILATION DIAGRAM 8 Heater Screen guard rail min 1 min 1 Locate vent u...

Страница 13: ...s spring or gravity loaded closures The door must always open outwards The warranty is void if a shower is installed in a sauna room No electrical receptacle shall be installed inside the sauna room T...

Страница 14: ...are in daily use should be washed down at least once a week to keep them clean and the air fresh Duckboard should be removed from the sauna the sauna floor mopped and dried in a conventional manner an...

Отзывы: