Specifications for the ConnectCore 6 Plus
Electrical characteristics
ConnectCore 6 Plus Hardware Reference Manual
87
Electrical characteristics
Voltage supplies
Parameter
Min
Typ Max Unit
5 V supply
4.2
5
5.5
V
VCC_LICELL 2.0
3.0
TBD V
LDO3_MCA
1.71 3.3
3.6
V
Note
No specific ESD protection components have been implemented on the ConnectCore 6 Plus
module. ESD protection level on the module’s I/Os is the same as what is specified in the NXP
datasheet. Any required ESD protection must be implemented on the carrier board.
Power consumption
This section contains data on the power consumption of the ConnectCore 6 and ConnectCore 6 Plus
system-on-module. The power is measured at the input of the SOM, i.e. VSYS input power rail. The
power architecture of the SOM requires some of the PMIC regulators to be externally powered. These
regulators are powered directly from some of the outputs of the PMIC itself (which are fed from VSYS).
No external circuitry is powered from any of the output power rails of the SOM, so that the power
measured at VSYS corresponds to the consumption of the SOM alone.
Note
These power consumption numbers should be considered guidelines only, never as fixed or
absolute values. Actual values will depend entirely upon individual setup and system application.
Power consumption use cases
This sections describes the use cases that were used to measure power consumption of the
ConnectCore 6 and ConnectCore 6 Plus system-on-module.
n
Suspend
System in suspend-to-RAM mode
n
Power-off
System in power-off with RTC enabled. RTC is running in the PMIC
n
IDLE
System up and running. Ethernet and wireless disabled
n
Decoding video
System up and running with the following configuration:
l
Ethernet and wireless disabled
l
HDMI display connected to the system
l
CPU decoding 1080p video
n
CPU stress
System up and running with the following configuration:
l
Ethernet and wireless disabled
l
Hanoi application running