Breakdown in the cargo cells due to overload (excess weight or impact incurred to 
the weighing platform). 

-

 

If the error continues, seek technical assistance. 

 

4.2

 

Error Five 

 
 

-

 

Look for a bad connection in the cables or a severed cable. 

-

 

Cargo cell burned by electrical surge.  (solder, lightning, short circuit, etc). 

-

 

In the case that there is no problem with the cargo cell, seek technical assistance. 

-

 

Breakdown in the cargo cell due to overload (excess weight or impact incurred to the 
weighing platform). 

-

 

In the case that the error persists, get in contact with technical assistance. 

-

 

Note:  In the case that error 5 is indicated, be it from impact to or overload of the 
weighing platform, it is because there is a discrepancy in the cargo cell.  The cargo 
cell will have to substitute and a new calibration will have to be done. 

4.3 Error Six 

 
 

 

-  Verify that the values were entered in Counter Mode. 

 

-  Verify that the values were entered within the configuration parameters. 

 
 
 
 
 
4.4 Error 7 

 

 
4.5 Error Eight 
 

 

-

 

Recharge the battery. 

-

 

Note:  If this error appears recharge the battery immediately.  Avoid running the 
scale by battery. 

4.6

 

Low Battery 

Description of error:  Overload on the scale 
beyond the cargo cell’s capacity.  This error only 
appears during scale operation. 

Description of error:  Incorrect data input. 

Description of error:  Insufficient operation 
tension to give a reliable weight reading. 

Description of error:  The clock battery is low.  
This problem only occurs when you check the 
clock for the first time after turning it on. 

Содержание ULPH

Страница 1: ...ale 5 3 Operation 6 Keypad functions 6 Zeroing 6 Automatic zero 6 Manual zero 6 Weighing 6 Setting the clock 7 RS 232 Serial Port 7 Communication with a computer terminal mode 8 Label printer 8 4 Troubleshooting 10 Error Zero 10 Error Five 10 Error Six 10 Error Seven 10 Error Eight 11 Low battery 11 Excess Weight 11 Underweight 11 Blinking display 11 Display with some segments dimly lit 12 Scale f...

Страница 2: ... to 700x700mm Fasten the articulated feet that are in the indicator s packaging Scales 800x800mm and up follow the following instructions Adjust the level and then lock the articulated feet using the nuts and bolts if the case may be The scale cannot undergo any kind of impact or overweighing on the weighing platform so that there is no damage to the load receptor Always place cargo as close to th...

Страница 3: ... This end should be plugged into the back of the weight indicator in the jack marked Load Cell After connecting thread the plug so that it does not slip during use If the plug is not well situated the scale may read weight inaccurately 2 4 Plugging In the Scale Having made the previous verifications and everything being in order the scale may be plugged in Plug in the scale and then turn the on of...

Страница 4: ...its After a successful weighing the zero indicator should be lit and the display showing zero In the case that the indicator does not light up the weight is too heavy and is out of the automatic zero range or the platform is oscillating In this case press the Z button to zero the reading on the display 3 5 Weighing Before starting a simple weighing verify these items The platform is empty There ar...

Страница 5: ...the clock see error 7 Pressing the L and I buttons in sequence will access the clock configuration mode Press Z to choose between setting the hour date day of the week and year Press T to set the clock Time Date Day of the Week Year Press the T button to choose the day of the week or place the cursor on the time date and year adjustments Press the L button to change the number above the cursor on ...

Страница 6: ... mode Quantidade byte significativo quantity byte significative Quantidade byte signifacativo quantity byte significative Retorno de carro carriage return Status status Fim de frame end of frame Figure 1 Stream for Weighing Mode The weight or the quantity is coded in ASC II with decimal point The carriage return character is 0x0D hexadecimal The sending of the stream is interrupted in the case tha...

Страница 7: ... Troubleshooting 4 1 Error Zero There could be weight on the platform upon turning on the scale Take the weight off the platform Moisture in the connectors Press I to print The ticket will be printed as long as there is a net weight greater than or equal to the minimum weight to print 20 unit divisions on top of the platform If the minimum is not met the display will blink indicating that there is...

Страница 8: ...the weighing platform it is because there is a discrepancy in the cargo cell The cargo cell will have to substitute and a new calibration will have to be done 4 3 Error Six Verify that the values were entered in Counter Mode Verify that the values were entered within the configuration parameters 4 4 Error 7 4 5 Error Eight Recharge the battery Note If this error appears recharge the battery immedi...

Страница 9: ...the instrument is not able to stabilize a zero reading Check for vibrations in the platform If the problem persists seek technical assistance 4 10 Display with some segments dimly lit 4 11 The Scale doesn t turn on Symptom The start up message may light up completely but shuts down immediately or lights up and shuts down before the start up is finished Description of error When the battery is low ...

Страница 10: ... function is activated If it turns on with the display brightly lit there is too much power Seek technical assistance If it lights up normally but it is not able to finish the start up there is not enough power Check the battery and recharge if necessary Symptom The scale turns off after the start up s 00000 Notes ...