Digi-Tron ULPH Скачать руководство пользователя страница 2

1. Introduction 

 

Dear User, 
 
This manual contains instructions on how to install and operate the Human Scale model ULPH, 
designed with technology and quality standards set by Digi-Tron, a company specialized in 
precision instruments. 
 
Its proper functioning, however, depends also on the treatment and care given by the user, as much 
in the installation as in its daily use.  It is, therefore, necessary to carefully read all the instructions 
contained in this manual, as well as abide by them. 
 
Only technicians certified by IPEM (Instituto de Pesos e Medidas/ Weights and Measures Institute) 
are allowed to open the instrument’s seal.  The breaking of the seal by persons not certified by 
IPEM will result in the automatic annulment of the Digi-Tron guarantee and violates federal laws. 
 
We recommend that any technical problem be directed to Digi-Tron´s Technical Assistance 
Department so that we may direct you to an authorized technician. 
 
2.

 

Installation 

Your product is a mass weighing instrument and you should take certain cautions during its use.  
Before putting your scale to use, it is important to observe the following items: 

-

 

Verify that the instrument has not suffered any damage during delivery. 

-

 

Check accessories 

-

 

Take off protective insulation.  (Instruments with dimensions up to 700x700mm) 

-

 

Fasten the articulated feet that are in the indicator’s packaging.  (Scales 800x800mm 
and up, follow the following instructions) 

-

 

Adjust the level and then lock the articulated feet using the nuts and bolts if the case 
may be. 

-

 

The scale cannot undergo any kind of impact or overweighing on the weighing 
platform so that there is no damage to the load receptor.  Always place cargo as close 
to the center of the scale as possible so that there is no lateral force on the load 
receptors and so that you get the best weight distribution over the entire scale. 

-

 

Do not use the keypad with sharp objects in order to avoid damages to the keypad’s 
circuits.   

-

 

The cleaning and keeping of the entire scale will also avoid unnecessary 
maintenance.  When possible, clean the scale with a damp cloth. 

-

 

Always clean the scale with the power cord unplugged. 

-

 

Always make sure that the scale’s cables and connectors are in perfect condition for 
they are essential for proper function. 

 
Maximum performance of your instrument depends on proper installation. 

 
2.1

 

Choosing an adequate location 

The place where the scale is installed must be level.  In the case of an uneven surface, compensate 
adjusting the leveling or articulated feet that are underneath the base. 
 
Inaccuracies in weighing can be caused by an uneven scale. 
 
Place the scale platform away from strong air currents. (Bench scales) 
 
Place the scale platform away from obstructing objects that my make access to the scale difficult. 

Содержание ULPH

Страница 1: ...ale 5 3 Operation 6 Keypad functions 6 Zeroing 6 Automatic zero 6 Manual zero 6 Weighing 6 Setting the clock 7 RS 232 Serial Port 7 Communication with a computer terminal mode 8 Label printer 8 4 Troubleshooting 10 Error Zero 10 Error Five 10 Error Six 10 Error Seven 10 Error Eight 11 Low battery 11 Excess Weight 11 Underweight 11 Blinking display 11 Display with some segments dimly lit 12 Scale f...

Страница 2: ... to 700x700mm Fasten the articulated feet that are in the indicator s packaging Scales 800x800mm and up follow the following instructions Adjust the level and then lock the articulated feet using the nuts and bolts if the case may be The scale cannot undergo any kind of impact or overweighing on the weighing platform so that there is no damage to the load receptor Always place cargo as close to th...

Страница 3: ... This end should be plugged into the back of the weight indicator in the jack marked Load Cell After connecting thread the plug so that it does not slip during use If the plug is not well situated the scale may read weight inaccurately 2 4 Plugging In the Scale Having made the previous verifications and everything being in order the scale may be plugged in Plug in the scale and then turn the on of...

Страница 4: ...its After a successful weighing the zero indicator should be lit and the display showing zero In the case that the indicator does not light up the weight is too heavy and is out of the automatic zero range or the platform is oscillating In this case press the Z button to zero the reading on the display 3 5 Weighing Before starting a simple weighing verify these items The platform is empty There ar...

Страница 5: ...the clock see error 7 Pressing the L and I buttons in sequence will access the clock configuration mode Press Z to choose between setting the hour date day of the week and year Press T to set the clock Time Date Day of the Week Year Press the T button to choose the day of the week or place the cursor on the time date and year adjustments Press the L button to change the number above the cursor on ...

Страница 6: ... mode Quantidade byte significativo quantity byte significative Quantidade byte signifacativo quantity byte significative Retorno de carro carriage return Status status Fim de frame end of frame Figure 1 Stream for Weighing Mode The weight or the quantity is coded in ASC II with decimal point The carriage return character is 0x0D hexadecimal The sending of the stream is interrupted in the case tha...

Страница 7: ... Troubleshooting 4 1 Error Zero There could be weight on the platform upon turning on the scale Take the weight off the platform Moisture in the connectors Press I to print The ticket will be printed as long as there is a net weight greater than or equal to the minimum weight to print 20 unit divisions on top of the platform If the minimum is not met the display will blink indicating that there is...

Страница 8: ...the weighing platform it is because there is a discrepancy in the cargo cell The cargo cell will have to substitute and a new calibration will have to be done 4 3 Error Six Verify that the values were entered in Counter Mode Verify that the values were entered within the configuration parameters 4 4 Error 7 4 5 Error Eight Recharge the battery Note If this error appears recharge the battery immedi...

Страница 9: ...the instrument is not able to stabilize a zero reading Check for vibrations in the platform If the problem persists seek technical assistance 4 10 Display with some segments dimly lit 4 11 The Scale doesn t turn on Symptom The start up message may light up completely but shuts down immediately or lights up and shuts down before the start up is finished Description of error When the battery is low ...

Страница 10: ... function is activated If it turns on with the display brightly lit there is too much power Seek technical assistance If it lights up normally but it is not able to finish the start up there is not enough power Check the battery and recharge if necessary Symptom The scale turns off after the start up s 00000 Notes ...

Отзывы: