18
• AC TRMS Current
(*) Accuracy specified from 5% to 100% of the measuring range, sine wave. Accuracy PEAK function:
±10%rdg , AC+DC TRMS Current: accuracy (50Hz÷1kHz): ±(3.0%r 20dgt).
• Flexible Coil Current
• Diode test
• Resistance and Continuity test
• Frequency (electronic circuits)
Sensitivity: 2Vrms
• Frequency (electronic circuits)
Sensitivity: >2Vrms (@ 20% 80% duty cycle) and f<100kHz;
>5Vrms (@ 20% 80% duty cycle) and f>100kHz
Range
Resolution
Accuracy
Protection against overcharge
600.0 μA
0.1 μA
±(1.2% r 5 digits)
Quick fuse 800mA/1000V
6000 μA
1 μA
60.00mA
0.01mA
600.0mA
0.1mA
10.00A
0.01A
±(1.5% r 8 digits)
Quick fuse 10A/1000V
Range
Resolution
Accuracy
Protection against overcharge
(50 Hz÷60 Hz)
(61 Hz÷1k Hz)
30.00A
0.01A
± (0.8%
reading
+ 5 digits)
±(2.4%
reading
+ 5 digits)
1000 VDC/ACrms
300.0A
0.1A
3000A
1A
Function
Test current
Max voltage with open circuit
<1.5mA
3.3VDC
Range
Resolution
Accuracy
Buzzer
Protection against overcharge
600.0
Ω
0.1
Ω
±(0.5% r 10 digits)
>50M
Ω
1000 VDC/ACrms
6.000k
Ω
0.001k
Ω
±(0.5% r 5 digits)
60.00k
Ω
0.01k
Ω
600.0k
Ω
0.1k
Ω
6.000M
Ω
0.001M
Ω
60.00M
Ω
0.01M
Ω
±(2.5% r 10 digits)
Range
Resolution
Accuracy
Protection against overcharge
40.00 Hz to 10k Hz
0.01 Hz to 0.001k Hz
±(0.5% reading)
1000 VDC/ACrms
Range
Resolution
Accuracy
Protection against overcharge
60.00 Hz
0.01 Hz
±(0.09% rdg +
5 digits)
1000 VDC/ACrms
600.0 Hz
0.1 Hz
6.000k Hz
0.001k Hz
60.00k Hz
0.01k Hz
600.0k Hz
0.1k Hz
6.000M Hz
0.001M Hz
10.00M Hz
0.01M Hz