DWL-5x000XY DATA SHEET
7.4.4. Calibration Mode
Byte [n]
Command
Descriptions
Byte [0]
0x06
From Computer
Byte [1]
0x0B
Dual Axis Mode
Byte [2]
0x01
0x01: To Sensor 1
0x02: To Sensor 2
0x03: To Sensor 3
0x04: To Sensor 4
0x05: To all sensors
Byte [3]
0xA0
0xA0 :Acknowledgement
0xB0 :Start current calibration step
Byte [4]~[11]
0x00
Not Applicable
Byte [n]
Command
Descriptions
Byte [0]
0x71
0x71: To Control Box / From Sensor 1
0x72: To Control Box / From Sensor 2
0x73: To Control Box / From Sensor 3
0x74: To Control Box / From Sensor 4
Byte [1]
0x1B
Single Axis Position / Calibration Mode
Byte [2]
0x00
Calibration Feedback
0x17 : Idle / Current calibration step finished
0x0A : Counting
Byte [3]
0x00
Calibration Count
0x01 - 0x1E : Counting Up
Byte [4]
0x13
Temperature Value
Byte [5]
0x01
Calibration Step
0x01: Calibration Step 1 ready
0x02: Calibration Step 2 ready
0x03: Calibration Step 3 ready
0x04: Calibration Step 4 ready
0x05: Calibration Step 5 ready
0x06: Calibration Step 6 ready
0x07: Calibration Step 7 ready
Byte [6]
0x88
Temperature Value
Byte [7]~[9]
0xDD
Fixed Dummy
Byte [10]
0x13
CRC16 High
Byte [11]
0x01
CRC16 Low
To set the tilt sensor module into Calibration Mode:
<< (To control box) :
0x06, 0x0B, 0x05, 0xA0, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00
<< (To control box) :
0x06, 0x0B, 0x05, 0xB0, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00
Data received from control box:
>> (From control box) :
0x71, 0x1B, 0x00, 0x00, 0x13, 0x01, 0x88, 0xDD, 0xDD, 0xDD, 0xAA, 0x3A