VECTORDRIVE DSV 5445
Top technology in drive electronics
07.07.04 10:12
Dietz-electronic
page 44 of 60
$[0c0c
only blocks 2,3 and 10, 11 free
e
Control on
v
Switch to speed control
#0
Basic setting A0
420
to be deleted...
#1
Position message A1
420
to be deleted
o[e08]
Travel with customer variable 5
;
;
:10
Counter-edge to input E2
w21
continue in subroutine block 21
;
;
:3
Run continuous speed - negative (input E3)
$[0c0c
only blocks 2,3 and 10,11 free
e
Control on
v
Switch to speed control
#0
Basic setting A0
420
to be deleted...
#1
Position message A1
420
to be deleted...
o[e08]n
Run customer variable 5 (negative)
;
:11
Counter-edge to input E2
w21
continue in subroutine block 21
;
:21
Interrupt speed subroutine (block 21)
v
Speed control on
o0
Stop
?[1ae
if motor stationary,
.
then continue
a
Control off
$[0c0f
Inputs/blocks 0,1,2,3 High-Fl., Low-Fl. 2,3 (block 10,11) free
8.4 Inverter communication modes
The description below of the transmission protocol only applies to the X4 serial interface.
8.4.1
"B3 mode" dialogue operation
Dialogue operation is available in on-line mode (function key F3) in the terminal program TER.EXE. The user
is guided by clear text messages. Dialogue operation is exited by selecting another communication mode. To
speed up a command program, switch to short message operation "B2 mode".