background image

CMi4160 

– LoRaWAN

®

 Module 

 

16  

02/2021 

DIB 

Field 

Size 

Data type 

Description 

*The  year  is  read  by  combining  the 
year-high  and  year-low  field.  For 
example,  year-high  =  0010  and  year-

low = 010 => year = 0010010   

 

**0 = standard time,  
1= daylight-saving time 

 
***0 = timestamp is valid,  
1 = timestamp is not valid 

Accumulated 
energy 

at 

24:00 

6-7 
Bytes 

INT32 

Energy consumption (Wh, J, Cal)  
 
4403xxxxxxxx = xxxxxxxx Wh 

4404xxxxxxxx = xxxxxxxx *10 Wh 
4405xxxxxxxx = xxxxxxxx *100 Wh 

4406xxxxxxxx = xxxxxxxx kWh 
4407xxxxxxxx = xxxxxxxx * 10 kWh 

440Exxxxxxxx = xxxxxxxx MJ 
440Fxxxxxxxx = xxxxxxxx * 10 MJ 
44FB0Dxxxxxxxx = xxxxxxxx MCal 

44FB0Exxxxxxxx = xxxxxxxx * 10 MCal 
44FB0Fxxxxxxxx = xxxxxxxx * 100 MCal 

 
Note:  Before  a  midnight  reading  has 
been  performed  the  Function  field  of 

the  DIF  is  set  to  “value  during  error 
state” to indicate that the value is not 

valid. 

Table 11: Payload, message format Scheduled – daily redundant 

 

Scheduled- Extended 
The  data  message  of 

Scheduled  mode-Extended

  contains  all  the  data  fields  from  message  format 

Standard.

 In addition to these, it also includes the meter date/time to transmit messages on the full 

hour. As for all 

Scheduled 

message formats, the transmit interval can only be set to the values included 

in 

Table 10

. 

A detailed description of the payload in the message format is presented in 

Table 12

. 

DIB 

Field 

Size 

Data type 

Description 

Message 
format 

identifier 

1 byte 

0x22 (Scheduled-Extended) 

Energy 

6-7 bytes 

INT32 

Energy consumption (Wh, J, Cal)  
 

0403xxxxxxxx = xxxxxxxx Wh 
0404xxxxxxxx = xxxxxxxx * 10 Wh 

0405xxxxxxxx = xxxxxxxx * 100 Wh 
0406xxxxxxxx = xxxxxxxx kWh 
0407xxxxxxxx = xxxxxxxx * 10 kWh 

040Exxxxxxxx = xxxxxxxx MJ 
040Fxxxxxxxx = xxxxxxxx * 10 MJ 

04FB0Dxxxxxxxx = xxxxxxxx MCal 
04FB0Exxxxxxxx = xxxxxxxx * 10 MCal 

04FB0Fxxxxxxxx  =  xxxxxxxx  *  100 

MCal 

Содержание LoRaWAN CMi4160

Страница 1: ...CMi4160 LoRaWAN Module For Diehl Metering SHARKY 775 User guide...

Страница 2: ...ection of battery pack 5 5 3 3 Connection of antenna 5 5 3 4 Network preparation 6 5 3 5 Activation 6 5 3 6 Switch off reboot module 7 6 Administration reference 7 6 1 Purpose 7 6 2 Security and acces...

Страница 3: ...nnel and to incorporate these guidelines into all user guides supplied with the product Failure to comply with these precautions violates safety standards of design manufacture and intended use of the...

Страница 4: ...ttery lifetime The module s EcoMode feature enables the module to achieve a battery lifetime of at least 11 1 years No meter installation needed As soon as the meter connectivity module has been mount...

Страница 5: ...r interface ribbon cable 3 5 3 2 CONNECTION OF BATTERY PACK The CMi4160 is delivered with a battery pack Connect the battery pack to the module s power connector 4 and gently place it with in the mete...

Страница 6: ...etwork join field in the Inspect tab of the OTC App Network join When activated CMi4160 will attempt to join the LoRaWAN network The phase is indicated by short flash on red light then green and red L...

Страница 7: ...f CMi4160 6 2 SECURITY AND ACCESS CONTROL CMi4160 has a configuration lock feature which prevents unauthorized access to the module When configuration lock has been enabled a Product Access Key will b...

Страница 8: ...attery life is guaranteed by adapting the transmit interval of the module to current signal conditions On Readable Writeable Readable Writeable Transmit interval Sets the number of minutes between eac...

Страница 9: ...e meter is assumed to be in standard local time no DST When synchronizing time in the meter using the OTC App local standard time is always used even if DST is in effect The timestamped meter data sen...

Страница 10: ...oMode table If a lower transmit interval is needed for the specific data rate in order to achieve 11 years of battery life the module will adjust the parameter accordingly Table 3 shows the transmit i...

Страница 11: ...s presented Standard Figure 5 illustrates the structure of message format Standard For a detailed description of the payload see Table 5 Figure 5 Structure message format Standard DIB Field Size Data...

Страница 12: ...m3 h 023Fxxxx xxxx 10 m3 h 5 Fw temp 4 bytes INT16 Forward temperature C 0258xxxx xxxx 0 001 C 0259xxxx xxxx 0 01 C 025Axxxx xxxx 0 1 C 025Bxxxx xxxx C 6 Rt temp 4 bytes INT16 Return temperature C 025...

Страница 13: ...address 10 bytes According to M Bus EN13757 3 identification field Meter address Byte 0 1 DIF VIF code Byte 2 5 Meter ID BCD8 lsByte msByte Byte 6 7 Meter manufacturer lsByte msByte Byte 8 Meter vers...

Страница 14: ...day and the data message at least regulated by transmit interval parameter or EcoMode once every day The transmit interval can only be set the values listed in Table 10 Note that although the meter r...

Страница 15: ...INT32 Volume m3 0413xxxxxxxx xxxxxxxx 0 001 m3 0414xxxxxxxx xxxxxxxx 0 01 m3 0415xxxxxxxx xxxxxxxx 0 1 m3 0416xxxxxxxx xxxxxxxx m3 0417xxxxxxxx xxxxxxxx 10 m3 3 Meter address 10 bytes According to M...

Страница 16: ...te to indicate that the value is not valid Table 11 Payload message format Scheduled daily redundant Scheduled Extended The data message of Scheduled mode Extended contains all the data fields from me...

Страница 17: ...flags 13 bytes INT72 Byte 0 3 DIF VIF codes 0x0DFF21E9 Byte 4 Error flags Byte 5 8 Meter ID BCD8 lsByte msByte Byte 9 10 Meter manufacturer lsByte msByte Byte 11 Meter version Byte 12 Device type 5 M...

Страница 18: ...040Fxxxxxxxx xxxxxxxx 10 MJ 04FB0Dxxxxxxxx xxxxxxxx MCal 04FB0Exxxxxxxx xxxxxxxx 10 MCal 04FB0Fxxxxxxxx xxxxxxxx 100 MCal 2 Cooling energy 8 9 bytes INT32 Energy consumption Wh J Cal 0483FF02xxxxxxxx...

Страница 19: ...is unable to communicate with the meter and retrieve meter values in which case all the fields in the payload have the DIF indicating value during error state In case of erroneous data or if the modul...

Страница 20: ...pact 0x20 Message format JSON 0x21 Message format Scheduled daily redundant 0x22 Message format Scheduled Extended 0x23 Message format Combined heat cooling 0x00070101F Sets the message format to comp...

Страница 21: ...erating humidity 0 93 RH No condensation Operating altitude 2 000 m Usage environment Indoors Storage temperature 20 60 C Radio characteristics Operating Frequency Frequency Band 863 1 864 9 K 865 1 8...

Страница 22: ...ion Description DIB Data Information Block DIF Data Information Field VIF Value Information Field MCM Meter Connectivity Module 9 2 NUMBER REPRESENTATION Decimal numbers are represented as normal numb...

Страница 23: ...CMi4160 LoRaWAN Module 23 02 2021...

Страница 24: ...www diehl com metering PfM 02 2021 Specifications subject to change without notice Diehl Metering GmbH Industriestra e 13 91522 Ansbach Phone 49 981 1806 0 Fax 49 9811806 615...

Отзывы: