background image

 

6

 

NOTE: 

Extended operation of a 12V DC 

device may result in excessive battery drain. 

Recharge the Portable Power immediately 

after unplugging the 12V DC device.

ESTIMATED RUN-TIMES 

APPLIANCE 

TYPE

EST WATTAGE ESTIMATED 

RUN TIME

Cell phone

4 watts

36 hrs

Fluorescent 

light

4 watts

36 hrs

Radios, fans

10 watts

16 hrs

Depth finder

10 watts

16 hrs

Camcorder

15 watts

9.6 hrs

Electrical tool

24 watts

6 hrs

Electric cooler

48 watts

3 hrs

Car vacuum,  

air compressor

80 watts

1.8 hrs

NOTE:

 Actual time may vary. Times are based on  

the internal battery being fully charged.

USING THE AIR COMPRESSOR
WARNING: 

Read the instructions of the 

product being inflated before using the 

compressor. Avoid overinflation; do not 

exceed the manufacturer’s recommended 

pressures. Do not leave the air compressor 

unattended during use.

1. 

Ensure the battery clamps are securely 

on the storage holders.

2. 

Remove the air compressor hose from 

the storage compartment in the back of 

the Portable Power. 

3. 

Connect the adapter to the valve 

stem by threading it onto the end. If 

necessary, use one of the additional 

adapters.

4. 

Place the compressor switch in the ON 

position and inflate the product.

5. 

When the product is inflated to 

the proper air pressure (using the 

air compressor gauge) place the 

compressor switch in the OFF position 

and remove the hose.

6. 

Do not run for more than 10 minutes 

maximum at a time. Allow the Portable 

Power to cool down for 10 minutes 

before using again.

NOTE:

 To prevent overheating, the 

compressor has built-in thermal protection 

that will turn the compressor off before it 

overheats. If the compressor shuts off, 

wait a few minutes and it will automatically 

restart when the compressor cools.

NOTE:

 The air compressor is rated for  

150 PSI.

ESTIMATED TIME FOR INFLATING

Vehicle Tires 13"-16"

5-8 minutes

Bike Tires

1-3 minutes

Sports Balls

30 seconds

These times are approximate. Use the air compressor 

gauge to ensure the proper pressure has been reached.

Do not overinflate.

6.  MAINTENANCE AND CARE

• Clean the clamps and the case each 

time you are finished using it. 

• Recharge the unit once a month when 

not in use. 

• Store clamps on their support posts, to 

ensure they do not come into contact 

with any metallic surface.

• Never completely discharge the internal 

battery. 

7.  TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

The Portable Power won’t 

jump start my car.

Clamps are not making 

a good connection to the 

battery.

Connections are reversed.

The Portable Power’s battery 

is not charged.

The vehicle’s battery is 

defective.

The Portable Power is not 

turned on.

Check for poor connection to 

battery and frame. Make sure 

connection points are clean. 

Disconnect the Portable Power 

and reverse the clamps.

Press the Battery Status button 

on the front of the unit. The 

LEDs will indicate the status of 

charge.

Have the battery checked. 

Turn the jump start ON/OFF 

switch to the ON position.

Содержание Portable Power 950 28.71687

Страница 1: ...ador OPERATOR S MANUAL MANUAL DEL USUARIO CAUTION Read and follow all safety rules and operating instructions before every use of this product SAVE THESE INSTRUCTIONS ATENCI N Lea y siga todas las reg...

Страница 2: ...lso have other rights which vary from state to state Schumacher Electric Corporation Mount Prospect IL 60056 FOR CUSTOMER ASSISTANCE OR REPLACEMENT PARTS CALL 1 800 732 7764 TOLL FREE DieHard is a reg...

Страница 3: ...attachment not recommended or sold by the jump starter s manufacturer may result in damage to the unit or personal injury Never operate the Portable Power if it is damaged If someone else uses the por...

Страница 4: ...ull charge yellow orange flashing Less than 30 of full charge CHARGING THE INTERNAL BATTERY Charge the internal battery for the Portable Power using an extension cord not included NOTE Use of an impro...

Страница 5: ...ock away from the battery 5 Turn the rotary switch to the ON position 6 Crank the engine for no more than 8 seconds If the engine does not start wait 2 minutes before cranking again 7 After the engine...

Страница 6: ...r more than 10 minutes maximum at a time Allow the Portable Power to cool down for 10 minutes before using again NOTE To prevent overheating the compressor has built in thermal protection that will tu...

Страница 7: ...a charge The battery is bad will not accept a charge Replace the battery The compressor shuts off before reaching the set pressure The compressor has a thermal cutoff to protect it from overheating W...

Страница 8: ...esorio no recomendado ni vendido por el fabricante del arrancador puede causar da o en la unidad o lesiones corporales Nunca opere la energ a port til si est da ado Si otra persona usa la energ a port...

Страница 9: ...el bot n Battery Status en la parte frontal de la unidad Las luces de LED indican el nivel de carga de la siguiente manera verde s lido 100 70 de carga completa amarillo naranja s lido 70 30 de carga...

Страница 10: ...s u otras partes m viles 3 En los veh culos con carga negativa a tierra como en la mayor a de los veh culos conecte la pinza con el polo POSITIVO ROJO de la energ a port til al borne POSITIVO POS P de...

Страница 11: ...tiempo real de funcionamiento puede variar Los tiempos est n basados en una bater a interna completamente cargada USO DEL COMPRESOR DE AIRE ADVERTENCIA Antes de usar el compresor lea las instruccione...

Страница 12: ...al Haga un chequeo de la bater a Gire el interruptor de arrancador ON OFF a la posici n de encendido La fenerg a port til no pone a funcionar mi aparato de 12V El aparato de 12V no enciende La bater a...

Отзывы: