7
Check the polarity of the battery posts. The POSITIVE (POS,
6.3
P, +) battery post usually has a larger diameter then the
NEGATIVE (NEG, N, -) post.
Determine which post of the battery is grounded (connected) to
6.4
the chassis. If the negative post is grounded to the chassis (as
in most vehicles), see step 6.5. If the positive post is grounded
to the chassis, see step 6.6.
For a negative-grounded vehicle, connect the POSITIVE
6.5
(RED) clip from the battery charger to the POSITIVE (POS,
P, +) ungrounded post of the battery. Connect the NEGATIVE
(BLACK) clip to the vehicle chassis or engine block away from
the battery. Do not connect the clip to the carburetor, fuel lines
or sheet-metal body parts. Connect to a heavy gauge metal part
of the frame or engine block.
For a positive-grounded vehicle, connect the NEGATIVE
6.6
(BLACK) clip from the battery charger to the NEGATIVE (NEG,
N, -) ungrounded post of the battery. Connect the POSITIVE
(RED) clip to the vehicle chassis or engine block away from the
battery. Do not connect the clip to the carburetor, fuel lines or
sheet-metal body parts. Connect to a heavy gauge metal part of
the frame or engine block.
Connect charger AC supply cord to electrical outlet.
6.7
When disconnecting the charger, turn all switches to off (if
6.8
applicable), disconnect the AC cord, remove the clip from the
vehicle chassis and then remove the clip from the
battery terminal.
See CALCULATING CHARGE TIME for length of
6.9
charge information.