TECHNICAL CHARACTERISTICS 

 

 

 
 

 
 
 
 
 
 
 

ELECTRICAL INSTALLATION 

 

 

 

 

 

         Minimum distance of cable to support base                                            Dismantle cover                                         Separate the power and signal cables at jack 
 

Technical Characteristics 

ELIOT 800AC 

NETWORK POWER SUPPLY 

230 Vac 50Hz 

MOTOR POWER SUPPLY 

230 Vac 

ABSORBED POWER 

422W 

CONSUMPTION 

1,85 A 

CONDENSER 

10

µ

THERMAL POWER 

 130ºC 

ENCODER 

Optical 

REVOLUTIONES OF ELECTRIC 
MOTOR 

1450 Rpm 

GATE SPEED 

10,8 m/min. 

TORQUE 

40 Nm 

LUBRICATION 

GRASA NLGI 0 

LIMIT SWITCHES 

Mechanical 

SERVICE TEMPERATURE 

 -20ºC to 70ºC 

LEVEL OF PROTECTION 

IP54 

WORK FACTOR 

40% 

WEIGHT 

11,5Kg 

COG MODULE 

M4 

MAX. WEIGHT OF GATE 

800Kg 

Содержание ELIOT 800AC

Страница 1: ...INSTRUCTION MANUAL SLIDING GATE AUTOMATION ELIOT Ed1 14 12 09 English ...

Страница 2: ...facturer will not be held responsible For protection against electrical overload or short circuit always install a 0 03 amp differential and a thermal magnetic switch with a contact aperture of at least 3mm This equipment must be earthed with a yellow green cable connected to the earth terminal in the junction box The safety of this product is only guaranteed if the equipment is properly earthed B...

Страница 3: ...RK POWER SUPPLY 230 Vac 50Hz MOTOR POWER SUPPLY 230 Vac ABSORBED POWER 422W CONSUMPTION 1 85 A CONDENSER 10µf THERMAL POWER 130ºC ENCODER Optical REVOLUTIONES OF ELECTRIC MOTOR 1450 Rpm GATE SPEED 10 8 m min TORQUE 40 Nm LUBRICATION GRASA NLGI 0 LIMIT SWITCHES Mechanical SERVICE TEMPERATURE 20ºC to 70ºC LEVEL OF PROTECTION IP54 WORK FACTOR 40 WEIGHT 11 5Kg COG MODULE M4 MAX WEIGHT OF GATE 800Kg ...

Страница 4: ...r motor 3 Rack M4 4 Nut M10 5 Washer M10 6 Leveling Nut 10 7 Base Plate 8 Rod M10x150 The B elevation indicates the distance from the centre of the rack to the door The A elevation indicates the distance between the edge of the base plate and the door B 30 ...

Страница 5: ...AUTOMATISM INSTALLATION ...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ... place 13 Position the motor parallel to the door 14 Fix the motor 15 Unblock the motor using the unblocking lever 16 Mount the rack with the screws and separators previously It is advised that the screws be fixed to the upper part of the mounting hole to allow the rack to be lifted in the future in the event of the door or floor guide suffering horizontal movements 17 Rest the first part of the r...

Страница 10: ...NIC PLATE E10035 12 ENCODER SET 95142 13 CONDENSATOR 15 mf 800AC 70456 14 CABLE DUCT exterior 70388 15 ELECTRIC MOTOR 800 95130 16 PLASTIC CASING 70384 17 COVER FIXING SET LEFT RIGHT 95143 18 MICRO LIMIT SWITCH SET 95125 19 MICRO UNBLOCKING SET 95126 20 SPROCKET PROTECTION COVER 70395 21 OUTPUT COG M4 Z16 70380 22 UNBLOCKING LEVER SET MED 95140 23 UNBLOCKING LEVER MED 70455 24 LOCK WITH SET OF KEY...

Отзывы: