background image

 
 
 

STEP BY STEP INSTALLATION OF THE AUTOMATISM 

 

1-

 

General dimensions of the plate 

2-

 

Position the plate parallel to the door. 
Mark A- Distance from the door to the edge of the plate. 
Mark B- Distance from the centre of the rack to the door. 

3-

 

Positioning the motor on the right. A minimum distance of 315mm is necessary for placing the limit switches. 

 

4-

 

Positioning the motor on the left. A minimum distance of de 375mm is necessary for placing the limit switches. 

 

5-

 

Use the plate as a template and pre-drill with a Ø8 bit. 

6-

 

Drill on the previously marked holes, with a Ø12 bit to a depth of 90mm. 

 

7-

 

Remove as much dust from the hole as possible and the resin from the inside of the hole outwards. 

 

8-

 

Insert the threaded rod with rotating movements and remove any excess resin. Screw in the M12 nut and position the 

plate. 

 

9-

 

Position the plate at a height of between 10 and 35mm from the ground, using the regulating nuts. 

 

10-

 

Level the plate, using a level

11-

 

Position the motor reducer on the plate. While doing so, pass the cables through the right cable duct. 

 

12-

 

Put the washers and mounting nuts in place. 

13-

 

Position the motor parallel to the door. 

14-

 

Fix the motor. 

15-

 

Unblock the motor, using the unblocking lever. 

16-

 

Mount the rack with the screws and separators previously. It is advised that the screws be fixed to the upper part of the 

mounting hole, to allow the rack to be lifted in the future, in the event of the door or floor guide suffering horizontal 
movements. 

 

17-

 

Rest the first part of the rack on the sprocket and fix it using a clamp. Move the door manually until reaching the final 

stretch of the rack and weld the last separator. 

 

18-

 

Move the door back and weld the rest of the separators

19-

 

Utilizar un tramo de unos 15cm. de cremallera para conservar el paso. 

20-

 

Fijar el tramo de 15cm con sargentos entre las dos cremalleras. Repetir la operación nº 17 en cada tramo de cremallera.  

 

21-

 

Loosen the height regulating nuts half a turn. 

22-

 

Allow a play of 1mm between the rack and the sprocket. 

23-

 

Tighten up the regulating nuts. 

24-

 

Put the side covers in place. 

25-

 

Pre-mount the limit switches.  

26-

 

Position the support in the centre of the mounting hole, allowing for future adjustments. 

27-

 

Position the limit switches on the correct side. 

28-

 

Manually  place  the  door  in  closed  position,  leaving  a  gap  of  1cm.  between  the  door  and  the  frame,  for  possible 

expansions. 

 

29-

 

Block the motor. 

 

 

Содержание ELIOT 800AC

Страница 1: ...INSTRUCTION MANUAL SLIDING GATE AUTOMATION ELIOT Ed1 14 12 09 English ...

Страница 2: ...facturer will not be held responsible For protection against electrical overload or short circuit always install a 0 03 amp differential and a thermal magnetic switch with a contact aperture of at least 3mm This equipment must be earthed with a yellow green cable connected to the earth terminal in the junction box The safety of this product is only guaranteed if the equipment is properly earthed B...

Страница 3: ...RK POWER SUPPLY 230 Vac 50Hz MOTOR POWER SUPPLY 230 Vac ABSORBED POWER 422W CONSUMPTION 1 85 A CONDENSER 10µf THERMAL POWER 130ºC ENCODER Optical REVOLUTIONES OF ELECTRIC MOTOR 1450 Rpm GATE SPEED 10 8 m min TORQUE 40 Nm LUBRICATION GRASA NLGI 0 LIMIT SWITCHES Mechanical SERVICE TEMPERATURE 20ºC to 70ºC LEVEL OF PROTECTION IP54 WORK FACTOR 40 WEIGHT 11 5Kg COG MODULE M4 MAX WEIGHT OF GATE 800Kg ...

Страница 4: ...r motor 3 Rack M4 4 Nut M10 5 Washer M10 6 Leveling Nut 10 7 Base Plate 8 Rod M10x150 The B elevation indicates the distance from the centre of the rack to the door The A elevation indicates the distance between the edge of the base plate and the door B 30 ...

Страница 5: ...AUTOMATISM INSTALLATION ...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ... place 13 Position the motor parallel to the door 14 Fix the motor 15 Unblock the motor using the unblocking lever 16 Mount the rack with the screws and separators previously It is advised that the screws be fixed to the upper part of the mounting hole to allow the rack to be lifted in the future in the event of the door or floor guide suffering horizontal movements 17 Rest the first part of the r...

Страница 10: ...NIC PLATE E10035 12 ENCODER SET 95142 13 CONDENSATOR 15 mf 800AC 70456 14 CABLE DUCT exterior 70388 15 ELECTRIC MOTOR 800 95130 16 PLASTIC CASING 70384 17 COVER FIXING SET LEFT RIGHT 95143 18 MICRO LIMIT SWITCH SET 95125 19 MICRO UNBLOCKING SET 95126 20 SPROCKET PROTECTION COVER 70395 21 OUTPUT COG M4 Z16 70380 22 UNBLOCKING LEVER SET MED 95140 23 UNBLOCKING LEVER MED 70455 24 LOCK WITH SET OF KEY...