HOPPERS FAIL TO ALARM WHEN SEED IS NOT
BLOCKING SENSOR. SELF-TEST INDICATED THE
SENSOR WAS PRESENT.
Probable Cause
1. Defective hopper sensor
2. Defective sensor or harness wire that is intermittent
3. Defective harness or sensor cable (signal shorted to power)
4. Hopper sensor is connected to seed input
Corrective Action
1. Clean sensing elements using a dry bottle brush. Some seed
treatments require scrubbing with water and a commercial cleanser.
2. Check module harness connections at the module and sensors. Check
module harness for pinched, worn, or broken elements. Check sensor
cables for pinched, worn, or broken elements.
3. Swap the sensor connection with another hopper connector or move
sensor. If the problem moves, the sensor is faulty. Otherwise the
harness or monitor is faulty. Check module harness for pinched, worn,
or broken elements. Check sensor for pinched, worn, or broken wires.
4. Assure hopper is connected to “ROW 16/HOPPER” connector input.
UNIT POWERS ON, ALL LEDS BLINK ON, AND NO
ERROR OCCURS, BUT NO SENSORS ARE
DETECTED ON A MODULE.
Probable Cause
1. Module harness is not properly connected
2. Defective (8V power or ground open) harness
3. Defective monitor or module
Corrective Action
1. Check module harness connections at the module and sensors.
2. Check module harness for pinched, worn, or broken elements.
3. Contact your Parts and Service Dealer or DICKEY-john in the U.S.A. at
1-800-637-3302. Outside of the U.S.A., contact your dealer or national
distributor or DICKEY-john Europe at 00 33 (0) 1 41 19 21 80.
UNIT DISPLAYS AN “E” FOLLOWED BY A MODULE
NUMBER
Probable Cause
1. 8V short error detected by Module
Corrective Action
1. Module voltage supply error. Check module harnesses and sensors for
short of 8V supply to ground. 8V supply is generated by each module
for its sensors.
Содержание DjASM II
Страница 1: ...OPERATOR S MANUAL...
Страница 3: ...Dj ASM II Air Seeder Monitor 11001 1311 200501 ii...
Страница 13: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 10 SYSTEM CONFIGURATION...
Страница 21: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 18 SYSTEM OPERATION...
Страница 27: ...OPERATOR S MANUAL Dj ASM II Air Seeder Monitor 11001 1311 200501 24 DJ ASM II SERVICE PARTS...