70 / VALVE CALIBRATION
Target Meter RPM
The speed at which the output meter shaft turns while the calibration is
performed.
Number (#) Meter Revs
NOTE:
If performing a Spreader
Calibration on a box type drill,
catch the output of a few seed
meters, average the weight
measured from these meters,
and multiply this average
weight by the total number of
meters on the drill. Enter this
weight for the Amount
Dispensed value.
The number of revolutions the meter turns during the calibration. This will
constitute the length of the test. The higher the number, the more accurate
the calibration.
Pulse Count
A pulse count that is produced from the feedback sensor. This number is
informational only.
New Spreader Constant
After the spreader calibration is performed and the amount is entered, press
the Save button to accept the new constant.
Amount Dispensed
Enter the amount (Lbs/Kg) dispensed after performing the spreader
constant calibration. The amount dispensed number is used with pulse
count and density to calculate the new spreader constant.
SHAFT TURN
The Shaft Turn button turns the shaft one (1) gear revolution and fills the
seed meter for instant seed flow when the control is turned on.