Test y Ajustes
50
IIIIII:
6 characters for amount
S:
amount sign (negative
“-“ 0x2Dh, positive “ “ 0x20h).
TTTT:
4 digits for the PLU tare
MMMMMMMMMMMMM:
13 digits for the PLU description that the scale ignores
(21 characters on the frame 5).
S
1
S
2
:
Status
0 0 :
Correct.
0 1 :
General error. Start-
up error, adjustment error…
0 2 :
Parity error or more than available characters. IS NOT
PROCESSED
1 0 :
Frame number incorrect (numeric field on header).
1 1 :
Base price not valid.
1 2 :
Tare not valid.
1 3 :
Received text not valid.IT IS NOT PROCESSED.
2 0 :
Unstable weight.
2 1 :
The weight does not vary from the last operation.
2 2 :
The amount is not calculated.
3 0 :
Minimum weight range. Weight 00.000
3 1 :
Negative weight
, “-------------“ on display.
3 2 :
Overload
, “------------“ on display.
NOTE:
-
This protocol is not for only weight scales.
-
If there is a parity error, frame number error, base price not valid, negative or zero weight or the scale
is in error status, the scale responds with
NAK
to frames 1, 2, 3 or 4.
-
When the scale is on any error status, it responds with
NAK
to the frame
E
T
E
Q
.
-
If the scale has a tare weight, it sends the net weight.
-
The scale wait until it has stable weight to responds to frames 1, 2, 3, 4 or 5.
-
The scale takes into account the minimum weight adjustment. If this adjustment has the value 1, the
scale responds with
NAK
if the weight is lower than 20 steps.
-
Between different requests the weight must vary at least 20 steps or pass through zero, otherwise the
scale responds with
NAK
and set the status to 21.
-
When the scale receives the frame 5 it responds with the same price and amount, it only adds the
weight.
Содержание DPOS400 SERIE
Страница 1: ...TEST AND ADJUSTMENTS MANUAL DPOS400 SERIE Ref 49 TGDP4ES02 V 1 08 ...
Страница 2: ......
Страница 72: ......