DPOS 400
49-TGDP4ES02
45
MMMMMMMMMMMMM:
13 digits for the PLU description that the scale ignores
(21 characters on the frame 5).
S
1
S
2
:
Status
4 9 :
Without changes from the last operation.
ñ 7 :
General error.
ñ 6 :
Correct.
NOTE:
-
If there is a parity error, frame number error, base price not valid, negative or zero weight or the scale
is in error status, the scale responds with
NAK
to frames 1,2,3,4 or 5.
-
If weight is unstable the scale responds with the momentary weight, received price and the amount to
the frame
E
T
E
T
E
Q
.
-
If the amount overflows the scale responds to the frame
E
T
E
T
E
Q
with the amount to 0.
-
If the scale has a tare weight, it sends the net weight.
-
When the scale receives the frame 5 it responds with the same price and amount, it only add the
weight.
-
The scale takes into account the minimum weight adjustment. If this adjustment has the value 1, the
scale responds with
NAK
if the weight is lower than 20 steps.
-
Between different requests the weight must vary at least 20 steps or pass through zero, otherwise the
scale responds with
NAK
.