58
&C
Data-Carrier-Detect (DCD) Signal
Control
&
DCD signal always on.
&
DCD follows carrier. (ON when carrier from remote modem is present.)
&D
Modem Reaction to DTR on-to-off
Modem reaction to DTR on-to-off transition greater than S25 setting. Modem WILL dial when
DTR is ON or goes from an OFF to ON state.
List of modem reactions:
N=No Action
1=Hang up if off-hook and autoanswer is disabled.
2=Hang up if off-hook and autoanswer is not disabled.
3=Switch to asynchronous command state.
4=Perform soft reset (like ATZ, profile is set by &Y).
List of
&Q
states:
a. &QØ, &Q5, &Q6
b. &Q1, &Q4
c. &Q2, &Q3
&F
Load Factory Default Configuration
&FØ
Restore factory configuration (default for PCs); with hardware flow control, error
correction and data compression active.
&F1
Restore factory configuration (default for MACs), with hardware flow control, error
correction and data compression active.
Note: For Direct Connect Mode, use
AT\N1 &KØ &Q6 &D2
.
&G
Guard Tone Selection
Set automatically based on ATi6 setting.
&GØ
Do not generate guard tones (US default).
&G1
Generate 550Hz guard tone (not supported).
&G2
Generate 1800Hz guard tone (World Wide support models only).
&K
Serial Port Flow Control
&KØ
None
&K3
Enable bidirectional hardware (RTS/CTS) flow control (default with
&FØ
and
&F1
).
a
b
c (Settings of
&Qn
)
&DØ
=
N
2
1
&D1
=
3
3
1
&D2
=
1
1
1
&D3
=
4
4
1