background image

17

6 - Mode d’emploi - V

ue et liste des pièces

NUMBER

INTERNAL CODE 1TANK

INTERNAL CODE 2 TANKS

INTERNAL ÒÒCODE 3 TANKS

DENOMINATION

1

O9015 

O9016 

O9017

tablette inférieure

2a

O9070 

O9070 

O9070 

joue gauche

2b

O9070 

O9070 

O9070 

joue droite

3

G139

G139 

G139 

aimant circulaire

5

XPIED/04

XPIED/04

XPIED/04

pied

6

F-TOP-1POT-S

F-TOP-2POT-S

F-TOP-3POT-S

top

7

O9071

O9071

O9071

glissière côteé droite et gauche 

8

F-&FE-POT-S

F-&FE-POT-S

F-&FE-POT-S

pot

9

F-&FE-FILTREPOT

F-&FE-FILTREPOT

F-&FE-FILTREPOT

filtre fond de pot

10

G136

G136

G136

robinet de vidange cuve

11

O9051

O9051

O9051

protection bulbes de cuve

13a

F-&FE-CHAMBRECOMB

F-&FE-CHAMBRECOMB

F-&FE-CHAMBRECOMB

chambre de combustion

13b

ISOLA/06

ISOLA/06

ISOLA/06

cordite /mètre

17

O9010

O9011 

O9012 

dos ventilé 

21

F-FA-1POT-S

F-FA-2POT-S

F-FA-3POT-S

face avant

23

G120

G120

G120

thermostat de sécurité

30

F-&FE-BACRECUP

F-&FE-BACRECUP

F-&FE-BACRECUP

bac récolteur d'huile usé

32

O9059 

O9060

O9060

 porte

34

O9089-2017

O9090-2017

O9091-2017

guide cheminée

35

O9051

O9052

O9053

bac a frite mécanique

36

O9086-2017

O9087-2017

O9088-2017

crédence

38

F-CHEMINEE

F-CHEMINEE

F-CHEMINEE

cheminée

39

ISOLA/02

ISOLA/02

ISOLA/02

protège cheminée -promatech

52a

G120 

G120 

G120 

bulbe (rouge) thermostat de securité

52b

O9051

O9051

O9051

bulbe (bleu)régulation -bloc sit

52c

G116B

G116B

G116B

bulbe (vert) thermomètre

54

G131-FRITEUSES   

G131-FRITEUSES   

G131-FRITEUSES   

bruleur circulaire TGP 15

55

F015

F015

F015

support bruleur

59a

F018

F018

F018

thermocouple

59b

G115-FRITEUSES

G115-FRITEUSES

G115-FRITEUSES

veilleuse 3 flammes

59c

G122-FRITEUSES

G122-FRITEUSES

G122-FRITEUSES

bougie d'allumage

60

O9086

O9086

O9086

support veilleuse

63

O9099

O9099

O9099

support rampe a gaz

67

F-&FE-RAMPE-1POT

F-&FE-RAMPE-2POT

F-&FE-RAMPE-3POT

rampe a gaz fini

68

O9056

O9056

O9056

fond de bac a frite

69

O9069

O9069

O9069

couvercle-disque

70

POIGNEE/02

POIGNEE/02

POIGNEE/02

poignée de couvercle

74a

O9062

O9062

O9062

charnière supérieure gauche

74b

/

/

O9062

charnière supérieure centrale

75

/

/

O9062

charnière inférieure centrale

76

O9062

O9062

O9062

charnière supérieure droite

77a

O9062

O9062

O9062

charnière inférieure gauche

77b

O9062

O9062

O9062

charnière inférieure droite

89

G083

G083

G083

thermostat sécurité-cuve vide(option)

90a

G201

G201

G201

vanne 710 Minisit

90b

G200

G200

G200

coupe circuit-SIT-sécurité

90c

G203

G203

G203

manette de commande minisit

91

O9098

O9098

O9098

support bloc SIT

92

G202

G202

G202

piezo

96

G124+G125

G124+G125

G124+G125

presse étoupe cuve+joint EPDM

99

G116B

G116B

G116B

themometre analogique JUMO

100

O9108

O9108

O9108

cache misère droit

101

O9109

O9109

O9109

cache misère gauche

102

G204

G204

G204

capot simple pour minisit

6.1.2   Recommended spare parts list (MecaFRYER)

Содержание MECA-FRYER 3B

Страница 1: ...Mod MIKA 3 MC Production code MECA FRYER 3B 01 2018 ...

Страница 2: ...MECA FRYER MANUAL FRYERS ...

Страница 3: ...ng technician 08 Adjusting the settings 09 Table 1 Gas Pressure Values and Categories in Various Countries 10 Table 2 Setting the Pressure and Consumption 10 Conversion for operation with a different type of gas 11 Replacing the nozzle of the main burner 11 Setting the primary air at the main burner 11 User instructions 12 Igniting the unit 12 Turning the unit off 13 Upkeep recommendations 13 Drai...

Страница 4: ...n how to use it and have read this user manual For any repairs contact only customer service centres authorised by the manufacturer and ask for genuine parts Failure to comply with these instructions may jeopardize the safety of the unit Never aim high pressure water jets at the unit to wash it Never cover any openings heat extraction vents or exhaust vents THIS APPLIANCE MUST BE INSTALLED BY AN A...

Страница 5: ...0 4 80 G25 m h 1 85 3 70 4 55 Injector G20 G25 Ø 3 4 3 4 3 4 G30 G31 Ø 2 15 2 15 2 15 Burners number 1 2 3 Pressure mbar G20 12 12 12 Pressure mbar G25 15 15 15 Pressure mbar G31 20 20 20 Air adjustment no no no Electrical connection 23v 16A 50Hz 23v 16A 50Hz 23v 16A 50Hz Pilot burner G20 G25 Ø 20 20 20 G30 G31 Ø adjustable adjustable adjustable 612 876 30 63 526 212 670 930 1455 Stainless steel A...

Страница 6: ...mer numéro pin pin number 230V 50 Hz 0 5 A Qn Hs V kW kW m h G20 G25 20 25 mbar 15 1 16 61 1 6 G31 37 mbar 12 6 13 86 0 51 G25 25 mbar 15 1 16 61 1 6 G30 30 mbar 12 6 13 86 0 51 G31 30 mbar 12 6 13 86 0 51 G20 25 mbar 15 1 16 61 1 6 G30 G31 IE 28 30 37 mBar A NL II2L3B P II2E 3P GB BE C GC p 12 6 13 86 0 51 II2E3 Qn Hi Dit toestel dient te worden geinstalleerd conform de geldende regels en mag enk...

Страница 7: ...o the gas supply should be performed using metal piping of an appropriate cross section an approved shutoff cock must be fitted upstream After connecting the gas supply use soap water to check for leaks at pipe joints The pressure is measured with a pressure gauge from 0 to 80 mbar accuracy at least 0 1 mbar The pressure connection is on the sit block Close the gas valve Unscrew the screw A of the...

Страница 8: ...on procedure may result in hazardous situations for which TEKNO LAM disclaims all responsibility If installation is not performed by an authorised installer the warranty will be invalidated In all cases damaged or worn parts must be replaced with genuine spare parts and must be installed by an authorised installer Any parts to be replaced under warranty must be returned to us no later than 8 days ...

Страница 9: ...njector if it not intended for the type of gas that you will use If the utilised gas is different from the type indicated on the data plate see p 3 please proceed as shown in the following picture NEVER SET A PRESSURE VALUE THAT IS HIGHER THAN SPECIFIED 2 In case of problems with the pilot burner such as the flame often going out adjust the pilot light as illustrated in the picture 1 Remove the ca...

Страница 10: ...25 25mb G31 37mb G20 20mb G25 25mb G31 37mb G20 20mb G25 25mb G31 37mb Pressure settings at each burner in mbar 12 15 20 12 15 20 12 15 20 12 15 20 Higher heating value HHV max kW 16 61 16 61 13 86 33 22 33 22 27 72 49 3 49 3 41 58 66 44 66 44 55 44 Lower heating value LHV max kW 15 1 15 1 12 6 30 2 30 2 25 2 45 3 45 3 37 8 60 4 60 4 50 4 Number of burners 1 1 1 2 2 2 3 3 3 4 4 4 Gas consumption i...

Страница 11: ...ed gas type as indicated in Table 2 p10 Shut the gas valve upstream of the unit 3 2 Setting the primary air at the main burner Start the unit according to the user instructions Check for leaks using soapy water Ignite the pilot flame according to instructions and check it To check the primary air setting at the main burners the X clearance must be set exactly as shown see image The primary air is ...

Страница 12: ...and never above the MAX mark Refer to the Technical Data Table p02 to determine the tank capacity MAX MIN FILLING THE BASKET The amount of food to be placed into the basket depends on the cooking method It is most important to avoid a sharp drop in temperature when dipping the food into the oil In any case oil temperature should never drop below 160 C Cooking small amounts of food for the right le...

Страница 13: ...fill the tanks above the lowest level In case of failure always call an authorised technician or retailer Fryers are equipped with a safety thermostat that trips if the oil overheats and turns off the appliance To restart the appliance you need to reset the thermostat This must be done by qualified service personnel who will also check the cause of tripping After about two hours of operation disco...

Страница 14: ...tes but when I release the button see the relevant description after 10 15 seconds the flame goes out by itself Generally this indicates a defective thermocouple component you MUST HAVE IT REPLACED Your appliance has a rock solid design and robustness according to optimum safety manufacturing standard My appliance keeps turning itself off Is your appliance properly connected There should be a mini...

Страница 15: ...ainless steel items with a cloth soaked in paraffin oil applying a protective film Periodically air out the room COOKING TANKS Empty the oil tanks by draining the oil off through the drain cock A down to the drip pan Afterwards clean the tanks using suitable detergent Do not scrape or scratch the bottom Rinse abundantly with water to remove any traces of detergent STAINLESS STEEL ITEMS Stainless s...

Страница 16: ...LLE 1 2 60 59b 59c 59a DÉTAIL H ECHELLE 1 4 52b 52a 52c 11 9 DÉTAIL I ECHELLE 1 1 13b Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client Bertrand Mecafryer piecse de rechanges conseillées n plan Vérifié par n A Rev Description mardi 7 mars 2017 11 54 47 B Auteur Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client n commande n plan Vérifié par n A ...

Страница 17: ... O9051 bulbe bleu régulation bloc sit 52c G116B G116B G116B bulbe vert thermomètre 54 G131 FRITEUSES G131 FRITEUSES G131 FRITEUSES bruleur circulaire TGP 15 55 F015 F015 F015 support bruleur 59a F018 F018 F018 thermocouple 59b G115 FRITEUSES G115 FRITEUSES G115 FRITEUSES veilleuse 3 flammes 59c G122 FRITEUSES G122 FRITEUSES G122 FRITEUSES bougie d allumage 60 O9086 O9086 O9086 support veilleuse 63...

Отзывы: