11
3 - Mode d’emploi -
Adaptation pour fonctionner à un autre type de gaz
3. CONVERSION FOR OPERATION WITH A DIFFERENT TYPE OF GAS
3.1 Replacing the nozzle of the main burner
- Open the cabinet door and remove the oil containers.
- Press the primary air regulator into the venturi tube.
- Using a 12 mm spanner, unscrew the nozzle and replace it with a suitable one for the selected gas type, as indicated in
Table 2 (p10).
Shut the gas valve upstream of the unit
3.2 Setting the primary air at the main burner
- Start the unit according to the user instructions.
- Check for leaks using soapy water. Ignite the pilot flame according to instructions and check it.
- To check the primary air setting at the main burners, the “X” clearance must be set exactly as shown (see image).
The primary air is properly set when the flame does not detach itself when the burner is cold and does not return when
the burner is hot.
- Check the ignition and flame compliance on maximum.
Содержание MECA-FRYER 3B
Страница 1: ...Mod MIKA 3 MC Production code MECA FRYER 3B 01 2018 ...