4.6     Troubleshooting

4.7     Fire safety

- Everything looks fine, but I get no gas :

Is your ventilation system on? Don’t forget to turn it on.

In the event of tank overheating, if the grease or oil catches fire, do the following :

Do not panic. Take the nearest lid and cover the burning tank. The fire will soon go out due to lack of oxygen.

The fryer is fitted with a safety device that turns off the appliance automatically at 210°

- The pilot burner does not ignite :

Is the ignition spark adequate? If not, check whether the ignition cable has become disconnected. If necessary, light the

pilot burner using a match and have your lighting system replaced.

- The pilot burner ignites, but when I release the button (see the relevant description, after 10-15 seconds, the

flame goes out by itself :

Generally, this indicates a defective thermocouple component; you 

MUST HAVE IT REPLACED

.

Your appliance has a rock-solid design and robustness, according to optimum safety manufacturing standard.

- My appliance keeps turning itself off :

Is your appliance properly connected? (There should be a minimum clearance of 15 cm above your exhaust chimney).

Could one of your tanks have become overheated? (The safety sensor is activated automatically). If one of your tanks

overheats, it is quite probable that the thermostat detector is defective. In this case, have it replaced right away.

Do not use this tank any more.

NEVER ATTEMPT TO DISMANTLE OR REPAIR THE APPLIANCE YOURSELF! 

DANGER OF DEATH !

NEVER, EVER, USE WATER TO PUT OUT THE FIRE !!!

THE MAXIMUM SAFETY THRESHOLDS SET IN FACTORY CAN NEVER BE CHANGED OR TAMPERED WITH.

Содержание MECA-FRYER 3B

Страница 1: ...Mod MIKA 3 MC Production code MECA FRYER 3B 01 2018 ...

Страница 2: ...MECA FRYER MANUAL FRYERS ...

Страница 3: ...ng technician 08 Adjusting the settings 09 Table 1 Gas Pressure Values and Categories in Various Countries 10 Table 2 Setting the Pressure and Consumption 10 Conversion for operation with a different type of gas 11 Replacing the nozzle of the main burner 11 Setting the primary air at the main burner 11 User instructions 12 Igniting the unit 12 Turning the unit off 13 Upkeep recommendations 13 Drai...

Страница 4: ...n how to use it and have read this user manual For any repairs contact only customer service centres authorised by the manufacturer and ask for genuine parts Failure to comply with these instructions may jeopardize the safety of the unit Never aim high pressure water jets at the unit to wash it Never cover any openings heat extraction vents or exhaust vents THIS APPLIANCE MUST BE INSTALLED BY AN A...

Страница 5: ...0 4 80 G25 m h 1 85 3 70 4 55 Injector G20 G25 Ø 3 4 3 4 3 4 G30 G31 Ø 2 15 2 15 2 15 Burners number 1 2 3 Pressure mbar G20 12 12 12 Pressure mbar G25 15 15 15 Pressure mbar G31 20 20 20 Air adjustment no no no Electrical connection 23v 16A 50Hz 23v 16A 50Hz 23v 16A 50Hz Pilot burner G20 G25 Ø 20 20 20 G30 G31 Ø adjustable adjustable adjustable 612 876 30 63 526 212 670 930 1455 Stainless steel A...

Страница 6: ...mer numéro pin pin number 230V 50 Hz 0 5 A Qn Hs V kW kW m h G20 G25 20 25 mbar 15 1 16 61 1 6 G31 37 mbar 12 6 13 86 0 51 G25 25 mbar 15 1 16 61 1 6 G30 30 mbar 12 6 13 86 0 51 G31 30 mbar 12 6 13 86 0 51 G20 25 mbar 15 1 16 61 1 6 G30 G31 IE 28 30 37 mBar A NL II2L3B P II2E 3P GB BE C GC p 12 6 13 86 0 51 II2E3 Qn Hi Dit toestel dient te worden geinstalleerd conform de geldende regels en mag enk...

Страница 7: ...o the gas supply should be performed using metal piping of an appropriate cross section an approved shutoff cock must be fitted upstream After connecting the gas supply use soap water to check for leaks at pipe joints The pressure is measured with a pressure gauge from 0 to 80 mbar accuracy at least 0 1 mbar The pressure connection is on the sit block Close the gas valve Unscrew the screw A of the...

Страница 8: ...on procedure may result in hazardous situations for which TEKNO LAM disclaims all responsibility If installation is not performed by an authorised installer the warranty will be invalidated In all cases damaged or worn parts must be replaced with genuine spare parts and must be installed by an authorised installer Any parts to be replaced under warranty must be returned to us no later than 8 days ...

Страница 9: ...njector if it not intended for the type of gas that you will use If the utilised gas is different from the type indicated on the data plate see p 3 please proceed as shown in the following picture NEVER SET A PRESSURE VALUE THAT IS HIGHER THAN SPECIFIED 2 In case of problems with the pilot burner such as the flame often going out adjust the pilot light as illustrated in the picture 1 Remove the ca...

Страница 10: ...25 25mb G31 37mb G20 20mb G25 25mb G31 37mb G20 20mb G25 25mb G31 37mb Pressure settings at each burner in mbar 12 15 20 12 15 20 12 15 20 12 15 20 Higher heating value HHV max kW 16 61 16 61 13 86 33 22 33 22 27 72 49 3 49 3 41 58 66 44 66 44 55 44 Lower heating value LHV max kW 15 1 15 1 12 6 30 2 30 2 25 2 45 3 45 3 37 8 60 4 60 4 50 4 Number of burners 1 1 1 2 2 2 3 3 3 4 4 4 Gas consumption i...

Страница 11: ...ed gas type as indicated in Table 2 p10 Shut the gas valve upstream of the unit 3 2 Setting the primary air at the main burner Start the unit according to the user instructions Check for leaks using soapy water Ignite the pilot flame according to instructions and check it To check the primary air setting at the main burners the X clearance must be set exactly as shown see image The primary air is ...

Страница 12: ...and never above the MAX mark Refer to the Technical Data Table p02 to determine the tank capacity MAX MIN FILLING THE BASKET The amount of food to be placed into the basket depends on the cooking method It is most important to avoid a sharp drop in temperature when dipping the food into the oil In any case oil temperature should never drop below 160 C Cooking small amounts of food for the right le...

Страница 13: ...fill the tanks above the lowest level In case of failure always call an authorised technician or retailer Fryers are equipped with a safety thermostat that trips if the oil overheats and turns off the appliance To restart the appliance you need to reset the thermostat This must be done by qualified service personnel who will also check the cause of tripping After about two hours of operation disco...

Страница 14: ...tes but when I release the button see the relevant description after 10 15 seconds the flame goes out by itself Generally this indicates a defective thermocouple component you MUST HAVE IT REPLACED Your appliance has a rock solid design and robustness according to optimum safety manufacturing standard My appliance keeps turning itself off Is your appliance properly connected There should be a mini...

Страница 15: ...ainless steel items with a cloth soaked in paraffin oil applying a protective film Periodically air out the room COOKING TANKS Empty the oil tanks by draining the oil off through the drain cock A down to the drip pan Afterwards clean the tanks using suitable detergent Do not scrape or scratch the bottom Rinse abundantly with water to remove any traces of detergent STAINLESS STEEL ITEMS Stainless s...

Страница 16: ...LLE 1 2 60 59b 59c 59a DÉTAIL H ECHELLE 1 4 52b 52a 52c 11 9 DÉTAIL I ECHELLE 1 1 13b Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client Bertrand Mecafryer piecse de rechanges conseillées n plan Vérifié par n A Rev Description mardi 7 mars 2017 11 54 47 B Auteur Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client n commande n plan Vérifié par n A ...

Страница 17: ... O9051 bulbe bleu régulation bloc sit 52c G116B G116B G116B bulbe vert thermomètre 54 G131 FRITEUSES G131 FRITEUSES G131 FRITEUSES bruleur circulaire TGP 15 55 F015 F015 F015 support bruleur 59a F018 F018 F018 thermocouple 59b G115 FRITEUSES G115 FRITEUSES G115 FRITEUSES veilleuse 3 flammes 59c G122 FRITEUSES G122 FRITEUSES G122 FRITEUSES bougie d allumage 60 O9086 O9086 O9086 support veilleuse 63...