![Diamond JAR-VLA Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/diamond/jar-vla/jar-vla_flight-manual_2493222049.webp)
DIAMOND AIRCRAFT
DA 20/100 Flight Manual
Emergency Procedures
Doc # 202-100-VLA
9 March, 2001
Page
DOT Approved
3 - 9
3.3.3. Fire
(a)
Engine Fire during Engine-Start-Up on the Ground
1.
Fuel Shut-off Valve
CLOSED
2. Throttle
FULL
3.
Master Switch (Battery)
OFF
4. Ignition
Switch
OFF
5.
Evacuate Airplane immediately
(b)
Engine Fire during Flight
1.
Fuel Shut-off Valve
CLOSED
2. Airspeed
(v
IAS
)
70 kts / 81 mph / 130 km/h
3. Flaps
T/O
4. Throttle
FULL
5.
Electric Fuel Pump
OFF
6. Cabin
Heat
CLOSED
7.
Perform emergency landing with engine
off according to paragraph 3.3.2
(c)
Electrical Fire including Smoke during Flight
1.
Master Switch (Battery)
OFF
2. Cabin
Air
OPEN
3.
Fire Extinguisher
use only if smoke development
continues.
CAUTION
If fire extinguisher is used, the cabin must be aerated.