![Diamond JAR-VLA Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/diamond/jar-vla/jar-vla_flight-manual_2493222017.webp)
DIAMOND AIRCRAFT
DA 20/100 Flight Manual
General
Doc # DA202-100-VLA
August 22, 2006
Page
Revision 4
1 - 8
1.9.2. Coolant
EVANS NPG+ waterless coolant or a comparable coolant must be used without water or other
additives.
WARNING
Water or water-containing coolant must
not
be added
in any case
to the cooling system.
CAUTION
The coolant manufacturer’s data for change/replacement, usage, and operation are to be
observed.
(a) Coolant Capacity:
Minimum
: 2.5 US qt. (2.4 liters)
Maximum
: 2.6 US qt. (2.5 liters)
(b) Reservoir Capacity:
Minimum
: 0.11 US qt. (0.1 liters)
Maximum
: 0.21 US qt. (0.2 liters)
NOTE
The level in the reservoir can be checked using the coolant dipstick. Excessive overfilling
of the reservoir can result in overflow during operation. In the event of a completely empty
reservoir, the coolant level in the dispatcher vessel on top of the engine must also be
checked.