2.5. POWERPLANT INSTRUMENT MARKINGS
Powerplant instrument markings and their color code significance are shown below:
Instrument
Red Line
= Lower Limit
Green Arc
= Normal
Operating Range
Yellow Arc
= Caution Range
Red Line
= Upper Limit
Tachometer -
*
600 - 2260 RPM 2260 - 2385 RPM
2385 RPM
Oil Temperature
Indicator
122° F
50° C
122- 266° F
50 - 130° C
- 266°
F
130° C
Cylinder Head
Temperature
Indicator
- - -
275°
F
135° C
Oil Pressure
Indicator
12 psi
0.8 bar
29 - 73 psi
2 - 5 bar
ABOVE 1440
RPM
12 – 29 psi
0.8 – 2 bar
BELOW 1440
RPM
73 - 102 psi
5 - 7 bar
102 psi
7 bar
*
Recommended nominal idle speed = 950 RPM
2.6. MISCELLANEOUS INSTRUMENT MARKINGS
Instrument
Red Line
= Lower Limit
Green Arc
= Normal
Operating Range
Yellow Arc
= Caution Range
Red Line
= Upper Limit
Voltmeter
8-11 Volts
12.5 - 16 Volts
11 - 12.5 Volts
16.1 Volts