DV154/154B LCD Monitor Service Guide
Circuit operation theory
7
+
+
G
A
K
+
VCC
OUT
ISSEN
GND
FB
COMP
R/C
V
R
E
F
7
6
4
3
5
2
1
8
+
C610
Q601
R619
R618
R613
R614 R615
R617
R612
R624
C606
C611
C618
C609
ZD602
C614
R610
Q603
C612
C608
R616
IC603
C617
IC601
D605
D606
D604
C613
R620
R623
(PE)
100V
1000P
SSS6N60A
1K
10K
1K
20K
.68
100K
47
10K
105C
25V
100U
105C
50V
4.7U
105C
50V
10U
(D)
50V
.022U
24V
(D)
50V
220P
100K
H945
(D)
50V
.1u
(D)
50V
1000P
(1%)
22K
MCR100-6
(OPEN)
105C
50V
10U
3842B
1N4148
1N4148
1N4148
105C
50V
10U
10K
4.7
VCC
Fig. 6
#6 Feedback circuit
PC123 is a photo-coupler and TL431 is a shunt regulation. They are used to detect the output voltage change and be the primary
and secondary isolation. When output voltage changes, the feedback voltage will be compared and duty cycle will be decided to
control the correct output voltage. (See Fig.7)