DV154/154B LCD Monitor Service Guide
Circuit operation theory
5
When the Q601 turns on, energy is stored in the transformer. During Q601 turn-off period, the stored energy is delivered to the
secondary of transformer. R607, C607 and D601 is a snubber circuit. R615 is current sense resistor to control output power. (See
Fig.4)
Fig. 4
#4 Rectifier and filter
D702 and C707 are to produce DC output. L702 and C708 are to suppress high Frequency switching spikes. R704 is a
dummy load. (See Fig.5)