Patriot Series Single Tank Product Manual
pg. 23
11. Control Error Codes (2)
Problem
Possible Cause
Solution
E3, Err-1003, Err-103 =
Control valve motor ran too
long and was unable to find
the next cycle position and
stalled
Motor failure during a
regeneration
Check motor connections. Press NEXT and REGEN
buttons for 3 seconds to resynchronize software
with piston position or disconnect power supply
from PC board for 5 seconds and then reconnect.
Foreign material built up
on piston and stack
assemblies creating
friction and drag enough
to time out motor
Replace piston and seal/stack assemblies. Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
Drive bracket not
snapped in properly that
reduction gears and
drive gear do not
interface
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect power
supply from PC board for 5 seconds and then
reconnect.
E4, Err-1004, Err-104 =
Control valve motor ran too
long and timed out trying to
reach home position
Drive bracket not
snapped in properly that
reduction gears and
drive gear do not
interface
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect power
supply from PC board for 5 seconds and then
reconnect.
Err-1006, Err-106, Err-116 =
MAV/SEPS/NHBP/AUX MAV
valve motor ran too long
and unable to find the
proper park position.
MAV = Motorized
Alternating Valve
SEPS = Separate Source
NHBP = No Hard Water
Bypass
AUX MAV = Auxiliary MAV
Control valve
programmed for ALT A
or B, NHBP, SEPS, or
AUX MAV without
having a MAV or NHBP
valve attached to
operate that function
Press NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
MAV/NHBP motor wire
not connected to PC
board
Connect MAV/NHBP motor to PC board two-pin
connection labeled DRIVE. Press NEXT and REGEN
buttons for 3 seconds to resynchronize software
with piston position or disconnect power supply
from PC board for 5 seconds and then reconnect.
MAV/NHBP motor not
fully engaged with
reduction gears
Press NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
Foreign material built up
on piston and stack
assemblies creating
friction and drag enough
to time out motor
Replace piston and seal/stack assemblies. Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
Содержание DCS6-120-125
Страница 1: ...Patriot Series Single Tank Product Manual pg 0 Patriot Single Tank Product Manual...
Страница 16: ...Patriot Series Single Tank Product Manual pg 15...
Страница 17: ...Patriot Series Single Tank Product Manual pg 16...
Страница 18: ...Patriot Series Single Tank Product Manual pg 17 9 System Specifications...
Страница 19: ...Patriot Series Single Tank Product Manual pg 18...