Patriot Series Single Tank Product Manual
pg. 24
11. Control Error Codes (3)
Problem
Possible Cause
Solution
Err-1007, Err-107, Err-117
= MAV/SEPS/NHBP/AUX
MAV valve motor ran too
short (stalled) while
looking the proper park
position.
MAV = Motorized
Alternating Valve
SEPS = Separate Source
NHBP = No Hard Water
Bypass
AUX MAV = Auxiliary MAV
Foreign material is lodged in
MAV/NHBP valve
Check motor connections. Press NEXT
and REGEN buttons for 3 seconds to
resynchronize software with piston
position or disconnect power supply
from PC board for 5 seconds and then
reconnect.
Mechanical binding
Check piston and seal/stack assemblies,
check reduction gears, drive gear
interface and check MAV/NHBP black
drive pinion on motor for jammed into
motor body. Press NEXT and REGEN
buttons for 3 seconds to resynchronize
software with piston position or
disconnect power supply from PC board
for 5 seconds and then reconnect.