Diamond H2O
N1022 Quality Drive / PO Box 170 / Greenville, WI 54942
Ph: (920) 757-5440 / (866) 757-9287 / Fax: (920) 757-5819
5.
CONTROL VALVE INSTRUCTIONS continued
5.5.
OEM GENERAL INSTRUCTIONS continued
Table 1 shows the time for the backwash, regenerative, and rinse cycles for the ten available
programming options. Six different programs are available for a softener, one for a regenerative
filter, and three programs for backwash only filters. When the control valve is used as a:
Softener: one or two backwashes occur and refill always occurs after the rinse cycle (P0 - P5)
Regenerative Filter: one backwash occurs and refill always occurs after the rinse cycle (P6)
Backwashing Filter: one backwash occurs (P7 through P9)
Table 1
Regeneration Cycles and Times for Different Programs
Program
All times in Minutes
C1
1
st
Backwash
C2
Regenerate
C3
2
nd
Backwash
C4
Rinse
C5
Fill
P0
3
50
3
3
1-99
P1
8
50
8
4
1-99
P2
8
70
10
6
1-99
P3
12
70
12
8
1-99
P4
10
50
Skipped
8
1-99
P5
4
50
Skipped
4
1-99
P6
12
6
Skipped
12
1-99
P7
6
Skipped
Skipped
4
Skipped
P8
10
Skipped
Skipped
6
Skipped
P9
14
Skipped
Skipped
8
Skipped
NOTE: Diamond H
2
O used P9 as the default.
NOTE: During regeneration the display will show C1, C2, etc. If the cycle is skipped, that cycle
number will not be displayed.
STEP 3SS:
If program P0 through P6 was selected, enter in the
minutes of fill using
▲
or
▼
. The allowable values
vary from a low of 1 to a high of 99. If program P7,
P8 or P9 was selected, this screen will not appear.
Press SET button to go to Step 4SS. Note: For each
minute of fill 0.5 gallons of water is added to the
solution tank. With Sodium Chloride, each 0.5 gallon
of water will dissolve 1.5 pounds of salt.
Page 9