10B
8
EN
Filter Cover
Filter
CLOSE
(A)
OPEN
(B)
10
10C
10A
1. Remove the filter cover and filter.
2. Remove the two screws on the UV-C lamp and pull out the UV-C lamp wire jack from the UV light board.(fig.11).
3. Insert the New UV-C lamp and tighten the two screws and replace the wire jack on the UV-C lamp board.
UV-C LAMP REPLACING
WARNING - If the dryer has been fitted with a filter, it will need to be replaced after 60,000
operations but will continue working for a further 15,000 operations but without the benefits of
the HEPA filter. At approximately 75,000 operations the red LED will be flashing on the window
positioned at the front of the cover and the unit will stop working until a replacement filter is fitted.
!
The sterilization function of UV-C lamp will be weakened after 3 years use, the UV-C lamp needs to be
replaced for maintaining proper function.