UM-PM-022
DA9318 Direct Charging Reference Board
User Manual
Revision 1.0
1-Mar-2017
CFR0012
21
of
27
© 2017 Dialog Semiconductor
7.2
Control Widgets
7.2.1
Enable/Disable Polling
The polling switch enables or disables polling of the device registers and the refreshing of the
registers
’ controls on the GUI interface.
Figure 15: Polling
7.2.2
Charging Status Indicators
The
Status Indicators
window, see
, displays the following information:
●
Pre-Charge
: When the battery voltage is below 3 V (V
BATLOW
), the battery is pre-charged at a
lower charge current of 128 mA.
●
Constant-Current
: When the battery voltage is above 3 V and below the constant voltage
threshold; this indicator will light green. This indictor will also light green in conjunction with the
Slave Charging
indicator during direct charger.
●
Constant-Voltage
: When the battery voltage reaches the master charger constant voltage
termination voltage threshold, this indicator will light green indicating charger is in constant
voltage.
●
Slave Charging
: This indicator will light green when slave charging (DA9318) is enabled
indicating direct charging.
●
DONE
: This indicator will light green when charge cycle is complete.
The update actions are as follows:
●
Read All Registers
– even if the hardware device is not being actively polled then all the
registers can be polled once by pressing this button.
Figure 16: Board Status
Figure 17: Read All Regs Button